1787.07. Standard for fabricating.
   (a)   Applicability.
      This section applies to the following fabricating operations using commercial asbestos:
      (1)   The fabrication of cement building products.
      (2)   The fabrication of friction products, except those operations that primarily install asbestos friction materials on motor vehicles.
      (3)   The fabrication of cement or silicate board for ventilation hoods; ovens; electrical panels; laboratory furniture; bulkheads; partitions, and ceilings for marine construction; and flow control devices for the molten metal industry.
   (b)   Standard.
      Each owner or operator of any of the fabricating operations to which this section applies shall either:
      (1)   Discharge no visible emissions to the outside air from any of the operations or from any building or structure in which they are conducted or from any other fugitive sources; or
      (2)   Use the methods specified by Section 1787.12 to clean emissions containing particulate asbestos material before they escape to, or are vented to, the outside air.
      (3)   Monitor each potential source of asbestos emissions from any part of the fabricating facility, including air cleaning devices, process equipment, and buildings that house equipment for material processing and handling, at least once each day, during daylight hours, for visible emissions to the outside air during periods of operation. The monitoring shall be by visual observation of at least fifteen seconds duration per source of emissions.
      (4)   Inspect each air cleaning device at least once each week for proper operation and for changes that signal the potential for malfunctions, including, to the maximum extent possible without dismantling other than opening the device, the presence of tears, holes and abrasions in filter bags and for dust deposits on the clean side of bags. For air cleaning devices that cannot be inspected on a weekly basis according to this paragraph, submit to the Commissioner, and revise as necessary, a written maintenance plan to include, at a minimum, the following:
         A.   Maintenance schedule.
         B.   Recordkeeping plan.
      (5)   Maintain records of the results of visible emission monitoring and air cleaning device inspections using a format similar to that shown in Figures 1 and 2 and include the following:
         A.   Date and time of each inspection.
         B.   Presence or absence of visible emissions.
         C.   Condition of fabric filters including presence of any tears, holes and abrasions.
         D.   Presence of dust deposits on clean side of fabric filters.
         E.   Brief description of corrective actions taken including date and time.
         F.   Daily hours of operation for each air cleaning device.
      (6)   Furnish upon request and make available at the affected facility during normal business hours for inspection by the Commissioner, all records required under this section.
      (7)   Retain a copy of all monitoring and inspection records for at least two years.
      (8)   Submit quarterly a copy of the visible emission monitoring records to the Commissioner if visible emissions occurred during the report period. Quarterly reports shall be postmarked by the thirtieth day following the end of the calendar quarter.
(Ord. 46-93. Passed 2-2-93.)