(A) An application for a building permit shall be filed in the office of the Community Development Administrator on forms prescribed by the Community Development Administrator, along with the fees for building permits, plan review, and inspections as prescribed in § 154.011, and other pertinent information.
(B) Such application shall contain and be accompanied with the following:
(1) The name and address of the owner, the name and address of the applicant, and the name and address of the contractor if known;
(2) Property identification number and legal description of the property;
(3) The estimated cost;
(4) A description of the uses to be established or expanded;
(5) A site plan drawn to scale containing the following:
(a) Actual dimensions of the lot to be built upon;
(b) Size, shape, and location of the use to be established or the structure to be constructed;
(c) Size, shape, and location of all existing buildings and uses on the lot;
(d) Auto parking area; and
(e) Lot area to be used.
(6) An approved ingress and egress permit shall be obtained from the appropriate state, county, or township responsible for road jurisdiction when any such structure or use requires installation of a new ingress and egress;
(7) Water supply and sewage disposal facilities, including a true and correct copy of any permit required by the county’s or state’s Health Department approving such facilities;
(8) For all proposed commercial, industrial, and multi-family projects with three or more units, and institutional projects, three full sets of architecturally sealed building plans and specifications shall be submitted and approved by the Community Development Administrator prior to issuance of a building permit. One set of digital building plans and specifications may be required upon the Community Development Administrator’s request;
(9) All plans for proposed commercial, industrial, multi-family, and institutional projects shall be submitted to, and approved in writing by, the appropriate fire protection district prior to issuance of a building permit in all fire protection districts that have adopted a fire protection code and that have advised the Community Development Administrator that a plan review is required;
(10) All plans for commercial, industrial, multi-family, and institutional projects shall also show:
(a) Ingress and egress;
(b) Off-street loading;
(c) Exterior lighting; and
(d) Location of signage.
(11) If the permit is for a single-family or two-family dwelling, additions to dwellings, or for a residential accessory structures and additions to, three full sets of building plans and specifications with square footage listed.
(Prior Code, 7 TCC 1-31(e))