1290.14 ELECTRICAL DISTRIBUTION SYSTEM.
   (a)   General requirements. Every park shall contain an electrical wiring system consisting of wiring, fixtures, equipment, and appurtenances, which shall be installed and maintained in accordance with the electric power provider's specifications regulating such systems.
   (b)   Power distribution lines. Main power lines shall be located underground. All conductors and cables shall be buried at least 36 inches below the ground surface and insulated and specially designed for the purpose. Such conductors shall be located not less than one foot radial distance from water, sewer, gas, or communication lines.
   (c)   Individual electrical connections.
      (1)   Each mobile home lot shall be provided with an approved disconnecting device and overcurrent protective equipment. The minimum service per outlet shall be in accordance with applicable codes.
      (2)   The mobile home shall be connected to the outlet receptacle by an approved type of flexible cable with connectors and a male attachment plug.
      (3)   Where the calculated load of the mobile home is more than 60 amperes, either a second outlet receptacle shall be installed or electrical service shall be provided by means of permanently installed conductors.
   (d)   Required grounding. All exposed non-current-carrying metal parts of mobile homes and all other equipment shall be grounded by means of an approved grounding conductor run with branch circuit conductors or other approved method of grounded metallic wiring. The neutral conductor shall not be used as an equipment ground for mobile homes or other equipment.
(Ord. 961, § 614. Passed 8-13-01.)