§ 151.063 ELECTRICAL DISTRIBUTION AND SERVICE.
   (A)   Underground electrical lines shall be at least 24 inches below ground surface and at least one- foot radial distance from sewer, water, gas or communications lines. If overhead power lines are installed, they shall be at least 18 feet above streets or roads. A minimum horizontal clearance of at least three feet shall be provided between overhead lines and any structure.
   (B)   Electrical outlets for each individual manufactured home space shall be provided.
      (1)   No connected electrical extension cord shall lie on the ground or be suspended less than seven feet from the ground above sidewalks or pathways.
      (2)   All electrical wiring, equipment and appurtenances shall be installed and maintained in accordance with the applicable codes and regulations of the village.
   (C)   All park streets shall be lighted with an average illumination of at least 150 watts every 150 feet, with additional lighting at potentially hazardous locations, such as park entrances, streets and walkways, or steps.
(Prior Code, § 18-309)