§ 150.157 HEATING FACILITIES.
   (A)   Facilities required. Heating facilities shall be provided in structures as required by this section.
   (B)   Residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 68° F. (20° C.) in all habitable rooms, bathrooms and toilet rooms based on the winter outdoor design temperature for the locality indicated in section R303.9 of the International Residential Code. Cooking appliances shall not be used, nor shall portable unvented fuel-burning space heaters be used, as a means to provide required heating.
   (C)   Heat supply. Every owner and operator of any building who rents, leases or lets one or more dwelling units, or sleeping units on terms, either expressed or implied, to furnish heat to the occupants thereof shall supply heat during the period from October 1 to April 30 to maintain a minimum temperature of 68° F. (20° C.) in all habitable rooms, bathrooms and toilet rooms.
   (D)   Installation of materials. All materials used shall be installed in strict accordance with the standards under which the materials are accepted and approved. In the absence of such installation procedures, the manufacturer’s instructions shall be followed. Where the requirements of referenced standards or manufacturer’s instructions do not conform to minimum provisions of this code, the provisions of this code shall apply. (IRC G2415.1)
   (E)   Room temperature measurement. The required room temperatures shall be measured three feet (914 mm) above the floor near the center of the room and two feet (610 mm) inward from the center of each exterior wall.
(Ord. 1806, passed 2-5-2018)