9-5-2-12: CHIMNEYS AND FIREPLACES:
AMENDMENT TO SECTION R-1004
FACTORY-BUILT FIREPLACES
   A.   Subsection R-1004.4 Unvented gas log heaters:
   Delete this subsection in its entirety and insert the following:
   Unvented fireplaces are not permitted to be installed under any circumstances.
AMENDMENT TO SECTION R-1006
EXTERIOR AIR SUPPLY
   A.   Subsection R-1006.1 Exterior air:
   Delete wording: "unless the room is mechanically ventilated and controlled so that the indoor pressure is neutral or positive"
   Add sentence: Factory-built or masonry fireplaces covered in this chapter shall be equipped with an exterior air supply to assure proper fuel combustion.
   B.   Insert Section R-1006.6 Spark arrestor:
   All fireplace chimneys shall have an approved spark arrestor installed.
(Ord. 2015-11, 5-21-2015; amd. Ord. 2021-18, 10-21-2021)