AMENDMENT TO SECTION 903
WEATHER PROTECTION
A. Insert Subsection R-903.5
R-903.5 All wood soffit fascia materials shall be primed on all sides prior to installation.
Exception: Treated lumber.
B. Insert Subsection R-903.6 Gutters and Downspouts
All structures shall be provided with gutters and downspouts unless omission is specifically permitted by the building official.
AMENDMENT TO SECTION R-905
REQUIREMENTS FOR ROOF COVERINGS
A. Subsection R-905.2.7.1 Ice protection:
Delete subsection in its entirety and insert the following:
All roofs of permanently heated structures shall have an ice barrier that consists of a self-adhering polymer modified bitumen sheet, in lieu of normal underlayment and extend from the eaves edge to a point at least twenty-four inches (24") inside the exterior wall line of the building and a minimum of twenty-four inches (24") on each side of any valley.
B. Subsection R-905.2.8.1 Base and cap flashing:
Add sentence: All asphalt shingled roofs shall have a drip edge installed along the bottom of all roof edges and along all gable ends.
Add Exception: Where the gutter system supplies an approved flashing to take the place of a drip edge along the bottom roof edge.
(Ord. 2015-11, 5-21-2015; amd. Ord. 2021-18, 10-21-2021)