1337.03 PLANS TO BE SUBMITTED.
   Plans, specifications and pertinent explanatory data required to be submitted in connection with an application for a permit to construct a swimming pool or any alteration, addition, remodeling or other improvement to an existing swimming pool, shall comply with the following requirements, as well as any other data as may be requested by the Health Department or the Building Division:
   (a)    Plans drawn to scale indicating all dimensions of the swimming pool;
   (b)    A profile plan drawn to scale indicating all dimensions of the swimming pool;
   (c)    A cross section of scum gutters and/or skimmers;
   (d)    Pipe diagram showing size of all pipes, inlets, outlets, make-up water lines, vacuum lines, waste and discharge lines, circulation and other piping;
   (e)    The pool equipment room layout, showing filters, their location, pumps, chlorinators, chemical feeders, flow meter gauges, sight glass, strainers, hair and lint interceptors, dimensions of filter room, its location, floor drain, sumps and other pertinent information;
   (f)    The liquid capacity of the pool;
   (g)    The liquid capacity of any wading pool;
   (h)   The kind, number and size of filters, including the square footage of the filter area in each unit;
   (i)    Top capacity in gallons per minute;
   (j)    A description of chemical feeders for soda ash and alum;
   (k)    The type, kind and description of chlorinator;
   (l)    A description of the gauges and water flow meter;
   (m)    A description of the skimmers and/or scum gutters;
   (n)    The type and range of testing equipment, including chlorine.
      (Ord. 1977-81. Passed 5-10-77.)