§ 157.058 ADDITIONAL REQUIREMENTS.
   (A)   The City Council may require additional conditions for any CUP to preserve the public welfare, health and safety of the community.
   (B)   All non-residential uses shall direct light away and shield light sources from residential zones.
Zoning District Requirements
R-1
R-2
R-6
B-2
MU-BR
MU-BI
I
PUD
Zoning District Requirements
R-1
R-2
R-6
B-2
MU-BR
MU-BI
I
PUD
Accessory structure setbacks
Front/ROW
25’
25’
35’/50’
35’
NA
40’
40’
****
Side/ROW
15’
15’
25’
35’
5’
30’
30’
****
Side/interior
10’
10’
10’
10’
5’
15’
15’
****
Rear
10’
10’
10’
30’
10’
30’
30’
****
From R-1/2 zoning
NA
NA
25’
30’
10’
40’
50’
****
Maximums
Impervious (%)
35
50
65
75
100
75
75
****
Building height
35’
35’
40’
45’
45’
50’
50’
****
Accessory building height
15’
Driveway width
24’
24’
30’
30’
30’
30’
30’
****
Minimums
Lot area (sq. ft.)
15,000
19,500
30,000
10,000
NA
30,000
30,000
****
Lot width
80’
130’
100’
100’
NA
100’
100’
****
Driveway width
12’
12’
24’
24’
24’
24’
24’
****
Pavement setbacks
Front/ROW
10’
10’
25’
10’
10’
10’
10’
****
Side/ROW
10’
10’
25’
10’
10’
10’
10’
****
Side/interior
5’
5’
25’
5’
5’
5’
5’
****
Rear
10’
10’
25’
5’
5’
5’
5’
****
From R-1/2 zoning
NA
NA
25’
25’
10’
***20’
***20’
****
Principal structure setbacks
Front/ROW
25’
25’
*35’/50’
35’
0’
40’
40’
****
Side/ROW
25’
25’
50’
**35’
0’
30’
30’
****
Side/interior
15’
^15’
^35’
10’
0’
15’
15’
****
Rear
20’
20’
40’
30’
0’
30’
30’
****
From R-1/2 zoning
NA
NA
NA
50’
10’
50’
50’
****
NOTES TO TABLE:
See each zoning district’s section of this chapter for additional requirements
* - In the R-6 District, principal structure front/ROW setbacks are 35’ from local streets and 50’ from arterial streets or highways.
^ - In the Multi-Family Residential Districts (R-2, R-6), minimum lot areas (including common areas) shall be 3 times the square footage of the building(s) footprint; interior side setbacks for common wall developments shall be 0’.
** - In the B-2 District, street side/ROW setback may be reduced to 30’ from a dedicated, but unimproved ROW.
*** - In the I Districts, if parcel is abutting or across the street from a residential district, parking/drive aisle setback must be 20’.
**** - In the PUD District, the requirements of the underlying zoning district shall be adhered to unless otherwise determined by the City Council
- All setbacks are measured from the property line, not street/curb/sidewalk.
- Front/ROW pavement setbacks do not apply to driveways leading to garage, only to parking areas.
- Driveway width maximum and minimum are measured at curb cut/street; other dimensions may be allowed if recommended by the City Engineer and approved by the City Council.
- Pavement includes curb when measuring setbacks.
- Pavement for sport courts and similar uses must be placed outside of utility easements (if easement is larger than setback).
- Minimum lot width is measured at the building setback line.
- Attached garages are part of the principal structure.
- Accessory structures must be placed outside of utility easements (if easement is larger than setback) and are not allowed in front of the primary structure in residential zones, regardless of setback listed.
- Utility buildings may be placed 5’ from the side and rear property lines but may not be placed in front of the front building line of the principle structure or within any utility easements.
- Fences may be built on the property line with permission of the affected neighbors).
- Decks accessed from the primary structure are considered part of that building and may not encroach the setbacks.
- Landscaping should be placed outside of utility easements; if within easement and work is performed, owner will not be compensated.
 
(Ord. passed 12-17-2014; Ord. 4, passed 4-27-2016)