In all areas of special flood hazard the following standards are required:
(a) Anchoring.
(1) All new construction and substantial improvements shall be anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy.
(2) All manufactured homes, not otherwise regulated by the Ohio Revised Code pertaining to manufactured home parks, shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. Methods of anchoring may include, but are not limited to, use of over-the- top or frame ties to ground anchors.
(b) Construction Materials and Methods.
(1) All new construction and substantial improvements shall be constructed with materials resistant to flood damage;
(2) All new construction and substantial improvements shall be constructed using methods and practices and minimize flood damage; and
(3) All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.
(c) Utilities. The following standards apply to all water supply, sanitary sewerage and waste disposal systems not otherwise regulated by the Ohio Revised Code:
(1) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the systems;
(2) New and replacement sanitary sewerage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharge from the systems into flood waters; and,
(3) On site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding.
(d) Subdivision Proposals.
(1) All subdivision proposals, including manufactured home subdivisions, shall be consistent with the need to minimize flood damage;
(2) All subdivision proposals, including manufactured home subdivisions, shall have public utilities and facilities such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage;
(3) All subdivision proposals, including manufactured home subdivisions, shall have adequate drainage provided to reduce exposure to flood damage; and
(4) All subdivision proposals, including manufactured home subdivisions, shall meet the specific standards of Section 1331.17
(f).
(e) Standards in Areas of Special Flood Hazard Without Base Flood Elevation Data. In all areas of special flood hazard identified as Zone A on the Flood Insurance Rate Map where base flood elevation data are not available from any source, the following provisions apply:
(1) New construction and substantial improvement of any residential, commercial, industrial, or other nonresidential structure shall have the lowest floor, including basement, elevated to at least two feet above the highest adjacent natural grade.
(Ord. 14-2004. Passed 4-15-04.)