(A) Buildings and temporary structures built or located within the town from and upon adoption of this ordinance shall be constructed in accordance with the requirements of the International Plumbing Code (IPC), 2018 Edition, as published by the International Code Council (ICC), specifically excluding all appendices.
(B) The said Code is incorporated herein by reference as if the same were more fully herein set out except as follows.
(1) Section 101.1 Title. Delete (Name of Jurisdiction). Insert (Town of Star Valley Ranch).
(2) Section 106.6.2 Fee schedule. Shall read, “For all buildings or structures requiring any permit, the fee for such permit shall be paid as set forth in the Town of Star Valley Ranch Code, §§ 150.035 through 150.050.”
(3) Section 106.6.3 Fee refunds. Shall read: “Refunds are described in the Town of Star Valley Ranch Code, §§ 150.035 through 150.050.”
(4) Section 108.4 Violation penalties. Shall read: “Penalties for infractions are described in the Town of Star Valley Ranch Code Chapter 35.”
(5) Section 108.5 Stop work orders. The last sentence shall read: “Stop work orders and penalties for non-compliance are described in the Town of Star Valley Ranch Code, Chapter 35.”
(6) Section 305.4 Freezing. Replace the last sentence with: “Exterior water supply systems piping shall be installed not less than six feet below grade.”
(7) Section 903.1 Roof extension shall read “All open vent pipes that extend through a roof shall be terminated at least 16 inches above the roof or six inches above the anticipated snow accumulation whichever is greater, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least seven feet above the roof.”
(8) Section 903.2 Frost enclosure. Amend the first sentence to read: “Every vent extension through a roof or wall shall be a minimum of 3 inches in diameter.”
(9) Section 100.3 Grease interceptors. Shall read: “Grease interceptors shall be approved by the Building Official and shall comply with the requirements of Sections 1003.3.1 through 1013.3.8. Interior grease interceptors shall be provided with a solids interceptor that shall separate the discharge before connecting to the grease interceptor.”
(Prior Code, § 6.08.010)