The following standards shall apply in areas of shallow flooding denoted as AO zones on the FIRM.
(A) All new construction and substantial improvements of residential structures shall have the lowest floor, including the basement, elevated above the crown of the nearest street or one foot above the base flood elevation, whichever is higher.
(B) All new construction and substantial improvements of non-residential structures shall have the lowest floor, including the basement, elevated one foot above the base flood elevation.
(Ord. 23-2, passed 2-9-2023)