1474.05 JOINTS.
   (a)    Control joints, whether hand-tooled or sawn, shall be to a depth of one-quarter the thickness of the slab. The dimension of any control joint panel shall not exceed ten feet.
   (b)   Isolation joints shall be required where concrete abuts a structure, including, but not limited to, foundations, garage floors, stoops and paved streets.
(Ord. 1982-34. Passed 11-8-82.)