§ 150.02 INTERNATIONAL RESIDENTIAL CODE ADOPTED BY REFERENCE.
   (A)   The village hereby adopts the 2018 International Residential Code, with all subsequent editions and amendments hereafter, by reference as if fully set out herein, with the additions, insertions, deletions and changes prescribed in division (B) of this section. All references to, and all functions served by, the “Board of Appeals” shall refer to and be served by the Code Hearing Department.
   (B)   The following sections of the 2018 International Residential Code are hereby amended, deleted or modified as hereinafter set forth:
      (1)   101.1 Title. Insert: “the Village of South Elgin, Kane County, Illinois” for “[name of jurisdiction].”
      (2)   105.2 Work exempt from permit. Delete: subsections 1, 2, 5 and 10.
      (3)   301.2 Insert: In Table:
 
Ground Snow Load
Wind Design
Seismic Design Category
Subject to Damage From
Speed (mph )
Topographic effects
Special wind region
Wind-borne debris zone
Weathering
Frost Line Depth
Termite
25 lb
115
NO
NO
NO
A
Severe
42"
Moderate Heavy
 
Winter Design Temp
Ice Barrier Under-layment Required
Flood Hazards
Air-Freezing Index
Mean Annual Temp
Minus 4
Yes
Yes*
2000
50
 
   *   (a) First entered into NFIP = July 6, 1981, (b) Flood Insurance Study(s) = January 16, 1981 & August 3, 2009, (c) FIRM Panel Numbers = 0169H, 0168H, 0256H, and 0251H
      (4)   Delete the section of Table R301.2(1) titled “MANUAL J DESIGN CRITERIA” and footnote “n”.
      (5)   313.1: Townhouse automatic fire sprinkler systems. Delete: An automatic residential fire sprinkler system shall be installed in townhouses. Insert: “A limited area fire sprinkler head is required in the vicinity of the furnace, laundry equipment, stove, and attached garage in townhouses.”
      (6)   313.2: One- and two-family dwellings automatic fire sprinkler systems. Delete: An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings. Insert: “A limited area fire sprinkler head is required in the vicinity of the furnace, laundry equipment, stove, and attached garage in one- and two-family dwellings.” Exception: Insert: “Homes located in the Sagebrook Subdivision and Trails of Silver Glen Subdivision.”
      (7)   403.1.1: Minimum size. After the first sentence, insert “Any structure which is not included within the provisions of Tables R403.1(l) through Table R403.1(3) shall have footings in accordance with Table R403.1(4).”
TABLE R403.1(4)
MINIMUM WIDTH OF CONCRETE OR MASONRY FOOTINGS (INCHES)a
 
Load Bearing Value of Soil (psf)
1,500
2,000
3,000
4,000
 
Load Bearing Value of Soil (psf)
1,500
2,000
3,000
4,000
Conventional light frame construction
1 story
12
12
12
12
2 story
15
12
12
12
3 story
23
17
12
12
4 inch brick veneer over light frame or 8 inch hollow concrete masonry
1 story
12
12
12
12
2 story
21
16
12
12
3 story
32
24
16
12
8 inch solid or fully grouted masonry
1 story
16
12
12
12
2 story
29
21
14
12
3 story
42
32
21
16
 
a.   Where minimum footing width is 12 inches, a single wythe of solid or fully grouted 12 inch nominal concrete masonry units is permitted to be used.
      (8)   507.1: Decks. After the last sentence, insert “Deck footings or piers must be at least 8 inches thick (T), sufficient width (W) to accommodate the imposed loads, and footing projections (P) shall not be less than 2 inches and shall not exceed the footing or pier thickness. (See R403.1.1)
      (9)   The Village of South Elgin hereby adopts the following Appendix:
         (a)   Appendix E: Manufactured Housing used as dwellings.
         (b)   Appendix F: Radon Control Methods.
         (c)   Appendix H: Patio Covers.
         (d)   Appendix O: Automatic Vehicular Gate.
         (e)   Appendix Q: Tiny Houses.
         (f)   Appendix T: Solar-Ready Provisions Detached One- and Two-Family Dwelling and Townhouses.
(Ord. 2004-20, passed 3-15-04; Am. Ord. 2006-57, passed 12-4-06; Am. Ord. 2009-29, passed 6-1-09; Am. Ord. 2009-43, passed 7-6-09; Am. Ord. 2011-13, passed 3-21-11; Am. Ord. 2014-33, passed 9-2-14; Am. Ord. 2018-07, passed 2-5-18)