§ 1250.12 STREETS ABUTTING INDUSTRIAL LOTS.
   Where a street abuts on industrial lots the following requirements shall apply.
   (a)   The minimum right-of-way shall be 70 feet in width.
   (b)   There shall be an additional easement ten feet in width adjacent to each side of the right-of-way to provide for the installation of underground power lines, telephone lines, cable television lines and gas mains.
   (c)   The improved portion of the right-of-way shall consist of a concrete pavement with square curbs and shall have a minimum width of 33 feet between the backs of curbs.
   (d)   Earthwork and subgrade preparation shall be in accordance with ODOT Item 203 and 206.
   (e)   The subbase shall consist of a three-inch layer of ODOT Item 304 limestone, 33 feet in width.
   (f)   Square concrete curbs shall be in accordance with ODOT Item 609, Type 2-A.
   (g)   The pavement shall consist of nine inches of fiber reinforced concrete in accordance with ODOT Item 451.
(Ord. 1991-19, passed 4-1-1991)