§ 153.335  WATER SUPPLY.
   The developer shall install or cause to be installed a water system for the subdivision by one of the following methods:
   (A)   Public system.
      (1)   A complete water main system which shall be connected to a public or other community water supply shall meet the requirements of the State of Ohio or other government authority having jurisdiction, and shall be approved by the City Engineer, the Zoning Enforcement Officer and the Planning Commission.
      (2)   The plans for the complete installation shall show size, location, depth, material and all connections thereto, including fire hydrants and valves.
      (3)   The subdivider shall furnish the Commission a complete set of plans and profiles as approved by the City Engineer and Zoning Enforcement Officer.
      (4)   In all instances, fire hydrants shall be spaced a maximum of 400 feet apart.
      (5)   No water main shall be less than eight inches in diameter with smaller mains being permitted with the approval of the City Engineer and Planning Commission, larger mains will be required where determined necessary by the City Engineer, Zoning Enforcement Officer and the Planning Commission.
      (6)   A water main shall be required to extend across the complete frontage of the subdivision to facilitate future development.
      (7)   On-site water production systems and facilities shall be prohibited within any minor or major subdivision.
(Ord. 09-3306, passed 10-15-09)