7-1-10: AMENDMENTS TO INTERNATIONAL BUILDING CODE:
The following terms, conditions, and provisions shall be incorporated into the codes adopted by this chapter, and shall be enforced as part of said codes. Section numbers prior to each item refer to those in the International Building Code.
101.1 - TITLE. Insert: "Shoshone County" as the NAME OF JURISDICTION.
Table 1
MINIMUM DESIGN CRITERIA
Wind Speed
Per IBC 1609
Air Freezing Index
1500
Seismic Design Category
C
Weathering
Severe
Minimum Frost Depth
30"
Assumed Minimum Soil Bearing Pressure
1500 psf
Decay
Slight
Ice Barrier Underlayment Required
Yes
 
1612.3 - Establishment of flood hazard areas: Flood hazard areas will be those areas as established through the Shoshone County Flood Plain Ordinance.
1809.5 - Frost protection: Minimum frost depth is 30" (thirty inches).
(Ord. 163, 5-18-2021)