1202.04 PLAT AND DATA REQUIREMENTS.
Subd. 1.   Sketch plan. The sketch plans shall contain, at a minimum, plat boundary, north arrow, graphic scale, street layout on and adjacent to plat, designation of land use and current or proposed zoning, significant topographical or physical features and general lot locations and layout.
Subd. 2.   Preliminary Plat. The subdivider shall prepare and submit a preliminary plat, together with any necessary supplementary information. The preliminary plat shall contain the information set forth in the subdivisions which follow.
      a.   General requirements.
         (1)   Proposed name of subdivision. Names shall not duplicate or too closely resemble names of existing subdivisions.
         (2)   Location of boundary lines in relation to a known section, quarter section or quarter-quarter section lines comprising a legal description of the property.
         (3)   Names and addresses of all persons having property interest, the developer, designer and surveyor, together with the surveyor’s registration number.
         (4)   Graphic scale. Scale shall be expressed as one inch to ten feet, 20 feet, 30 feet, 40 feet, 50 feet, 60 feet or 100 feet.
         (5)   Date of preparation and north arrow.
      b.   Existing conditions.
         (1)   Survey, prepared by a registered land surveyor, showing boundary lines and total acreage of proposed plat clearly indicated.
         (2)   Existing zoning classifications for land within and abutting the subdivision.
         (3)   Location, widths and names of all existing or previously platted streets or other public or private ways showing type, width and condition of improvements, if any. Location, width and names of all existing railroad and utility rights-of-way, parks and other public open spaces, permanent buildings and structures, easements and section and corporate lines within the tract and to a distance of 300 feet beyond the tract.
         (4)   Location and size of existing sewers, water mains, stormwater pipes, culverts, drainage tiles or other underground facilities within the tract and to a distance of 100 feet beyond the tract. The data as grades, invert elevations, locations of catch basins, manholes and hydrants shall also be shown.
         (5)   Boundary lines of adjoining unsubdivided or subdivided land, within 300 feet identified by name and ownership, including all contiguous land owned or controlled by the subdivider.
         (6)   Topographic data, including contours at vertical intervals of not more than two feet. Lakes, water courses, wetlands, rock outcrops, power transmission poles and lines, vegetation and other significant features shall also be shown.
         (7)   Statement of interest in the plat by the Minnehaha Creek Watershed District or the Riley-Purgatory-Bluff Creek Watershed District.
      c.   Design features.
         (1)   Layout of proposed streets showing the right-of-way widths, centerline gradients, typical cross sections and proposed names of streets in conformance with city and county street identification policies. The name of any street heretofore used in the city or its environs shall not be used unless the proposed street is a logical extension of an already named street, in which event the same name shall be used.
         (2)   Locations and size of proposed sewer lines and watermains or water wells.
         (3)   Locations and widths of proposed alleys and pedestrian ways.
         (4)   Location, dimension and purpose of all easements.
         (5)   Layout, numbers, lot areas and preliminary dimensions of lots and blocks. All lots shall be numbered clockwise in each block and blocks shall be numbered consecutively.
         (6)   Minimum front, side and rear building setback lines.
         (7)   When lots are located on a curve, the width of the lot at the building setback line.
         (8)   Areas, other than streets, alleys, pedestrian ways and utility easements, intended to be dedicated or reserved for public use, including the size of the area or areas in square feet and acres.
         (9)   A statement of the proposed use of lots stating type of buildings with number of proposed dwelling units or type of business, so as to reveal the effect of the development on traffic, fire hazards and congestion of population.
            (10)   Public utilities, including water, sanitary sewer mains and service connections to be installed in accordance with the standards of the city.
            (11)   Proposed grading, including existing and proposed contours at vertical intervals of not more than two feet, proposed cut and fill areas, proposed building pads showing type of house (full basement, walkout, split entry and the like) and elevations of lowest floor and garage floor.
            (12)   Proposed ponding data, including the ordinary high water level, high water level and emergency overflow elevation and route.
      d.   Supplementary information.
         (1)   Any or all of the supplementary information requirements set forth in this subdivision shall be submitted, when deemed necessary by the city staff, consultants, advisory bodies or City Council.
         (2)   Proposed protective covenants.
         (3)   An accurate soils report of the subdivision prepared by a registered professional engineer qualified to perform and analyze soil materials under the laws of Minnesota. The soils report shall consist of test holes to a depth necessary to determine the various types of soils to be encountered before reaching a stable base and the static water table elevation. The test holes, when ordered by the city authorities, shall be drilled at the expense of the owner or developer and the information disclosed shall be furnished to the city, together with a copy of the proposed plat showing the location of each test hole. The information required by the city shall include a report as to the various types of soils encountered and their depths, the level of the ground water, a percolation test and may include additional information. The number of test holes to be drilled and their location on the property, which is proposed to be platted, will be as directed by the city or their authorized representative. The owner shall be required to furnish to the city a report from a recognized engineering laboratory as to the safety and practicability of the use of the area for building construction.
         (4)   A survey prepared by a qualified landscape architect, forester or arborist identifying tree coverage in the proposed subdivision in terms of type, weakness, maturity, potential hazard, infestation, vigor, density and spacing.
         (5)   If any zoning changes are contemplated, the proposed zoning plan for the areas, including dimensions, shall be shown. The proposed zoning plan shall be for information only and shall not vest any rights in the applicant.
         (6)   Provision for surface water disposal, ponding, drainage and flood control.
         (7)   Where the subdivider owns property adjacent to that which is being proposed for the subdivision, it shall be required that the subdivider submit a sketch plan of the remainder of the property so as to show the possible relationships between the proposed subdivision and the future subdivision. In any event, all subdivisions shall be required to relate well with existing or potential adjacent subdivision.
         (8)   Where structures are to be placed on large or excessively deep lots that are subject to potential replat, the preliminary plat shall indicate a logical way in which the lots could potentially be subdivided in the future.
         (9)   A plan for soil erosion and sediment control both during construction and after development has been completed. The plan shall include gradients of waterways, design of velocity and erosion control measures, design of sediment control measures and landscaping of the erosion and sediment control system.
            (10)   A vegetation preservation and protection plan that shows those trees proposed to be removed, those to remain and the types and locations of trees and other vegetation that are to be planted.
            (11)   The other information as may be required.
Subd. 3.   Final Plat. The owner or subdivider shall submit a final plat, together with any necessary supplementary information. The Final Plat shall be prepared in accordance with provisions of Minnesota State Statutes and Hennepin County regulations, and the final plat shall contain the following information:
      a.   Name of the subdivision, which shall not duplicate or too closely approximate the name of any existing subdivision;
      b.   Location by section, township range, county and state and including descriptive boundaries of the subdivision, based on an accurate traverse, giving angular and linear dimensions which must mathematically close;
      c.   Name and address of surveyor making the plat;
      d.   Scale of plat (the scale to be shown graphically on a bar scale), date and north arrow;
      e.   The location of monuments shall be shown and described in reference to existing official monuments on the nearest established street lines, including true angles and distances to the reference points or monuments;
      f.   Location of lots, streets, public highways, alleys, parks and other features with accurate dimensions in feet and decimals of feet, with the length of radii and arcs of all curves and with all other information necessary to reproduce the plat on the ground. Dimensions shall be shown from all angle points of curve to lot lines;
      g.   Lots shall be numbered clearly in a clockwise progression. Blocks are to be numbered with numbers shown clearly in the center of the block;
      h.   The exact locations, widths and names of all streets to be dedicated;
      i.   Statement dedicating all streets, alleys and other public areas not previously dedicated as follows: streets, alleys and other public areas shown on this plat and not heretofore dedicated to public use are hereby so dedicated;
      j.   The exact locations and widths of all easements to be dedicated;
      k.   Statement dedicating all easements as follows: easements for installation and maintenance of utilities and drainage facilities are reserved over, under and along the strips marked “utility easements;”
      l.   Detailed plans and specifications in accordance with the City of Shorewood Standard Specifications for Construction of Public Utilities, including sanitary sewer, municipal water systems or on-site water supply, grading, drainage and erosion control plans, all approved by the City Engineer;
      m.   Evidence that ground water controls are provided at least ten feet below level of finished grades of plan;
      n.   Comply with rules and regulations of the Minnehaha Creek Watershed District, or Riley-Purgatory-Bluff Creek Watershed District, whichever District has jurisdiction or statement from the District indicating that it has no interest in the plat;
      o.   Any supplementary engineering data required by the city.
Subd. 4.   Certification required.
      a.   Certification by registered surveyor in the form required by M.S. § 505.03, as amended.
      b.   Execution by all owners of any interest in the land or any holders of a mortgage thereon of the certificates required by M.S. § 505.03, as amended, and which certificate shall include a dedication of the utility easement and other public areas in the form as approved by the City Council.
      c.   Space for certificates of approval and review, including the date of approval and spaces to be filled in by the signature of the Mayor and City Administrator/Clerk.
(Am. Ord. 380, passed 2-11-2002)