1460.23   GENERAL.
   (a)   Alteration or Relocation of Watercourse.
      (1)   No encroachment, alteration, or improvement of any kind shall be made to any watercourse until all adjacent municipalities which may be affected by such action have been notified by the municipality, and until all required permits or approvals have first been obtained from the Department of Environmental Protection Regional Office.
      (2)   No encroachment, alteration, or improvement of any kind shall be made to any watercourse unless it can be shown that the activity will not reduce or impede the flood carrying capacity of the watercourse in any way.
      (3)   In addition, FEMA and the Pennsylvania Department of Community and Economic Development, shall be notified prior to any alteration or relocation of any watercourse.
   (b)   (1)   When a community proposes to permit the following encroachments:
         A.   Any development that causes a rise in the base flood elevations within the floodway;
         B.   Any development occurring in Zones Al-30 and Zone AE without a designated floodway, which will cause a rise of more than one foot in the base flood elevation; or
         C.   Alteration or relocation of a stream (including but not limited to installing culverts and bridges).
      (2)   The applicant shall (as per 44 CFR Part 65.12):
         A.   Apply to FEMA for conditional approval of such action prior to permitting the encroachments to occur.
         B.   Upon receipt of the Administrator's conditional approval of map change and prior to approving the proposed encroachments, a community shall provide evidence to FEMA of the adoption of floodplain management ordinances incorporating the increased base flood elevations and/or revised floodway reflecting the post-project condition.
         C.   Upon completion of the proposed encroachments, a community shall provide as-built certifications. FEMA will initiate a final map revision upon receipt of such certifications in accordance with 44 CFR Part 67.
   (c)   Any new construction, development, uses or activities allowed within any identified floodplain area shall be undertaken in strict compliance with the provisions contained in this chapter and any other applicable codes, ordinances and regulations.
   (d)   Residential Structures.
      (1)   In AE, A1-30, and AH Zones, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation.
      (2)   In A Zones, where there are no base flood elevations specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation determined in accordance with Section 1460.19(c).
      (3)   The design and construction standards and specifications contained in the 2009 International Building Code (IBC) and in the 2009 International Residential Code (IRC) or the most recent revisions thereof and ASCE 24 and 34 PA Code (Chapters 401-405 as amended) shall be utilized, where they are more restrictive.
   (e)   Non-residential Structures.
      (1)   In AE, A1-30 and AH Zones, any new construction or substantial improvement of a non-residential structure shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation, or be designed and constructed so that the space enclosed below the regulatory flood elevation:
         A.   Is floodproofed so that the structure is watertight with walls substantially impermeable to the passage of water and,
         B.   Has structural components with the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.
      (2)   In A Zones, where no base flood elevations are specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated or completely floodproofed up to, or above, the regulatory flood elevation determined in accordance with Section 1460.19(c).
      (3)   In AO Zones, any new construction or substantial improvement shall have their lowest floor elevated or completely floodproofed above the highest adjacent grade to at least as high as the depth number specified on the FIRM.
      (4)   Any non-residential structure, or part thereof, made watertight below the regulatory flood elevation shall be floodproofed in accordance with the W1 or W2 space classification standards contained in the publication entitled "Flood-Proofing Regulations" published by the U.S. Army Corps of Engineers (June 1972, as amended March 1992) or with some other equivalent standard. All plans and specifications for such floodproofing shall be accompanied by a statement certified by a registered professional engineer or architect which states that the proposed design and methods of construction are in conformance with the above referenced standards.
      (5)   The design and construction standards and specifications contained in the 2009 International Building Code (IBC) and in the 2009 International Residential Code (IRC) or the most recent revisions thereof and ASCE 24 and 34 PA Code (Chapters 401-405 as amended) shall be utilized, where they are more restrictive.
   (f)   Space Below the Lowest Floor.
      (1)   Fully enclosed space below the lowest floor (excluding basements) which will be used solely for the parking of a vehicle, building access, or incidental storage in an area other than a basement, shall be designed and constructed to allow for the automatic entry and exit of flood waters for the purpose of equalizing hydrostatic forces on exterior walls. The term "fully enclosed space" also includes crawl spaces.
      (2)   Designs for meeting this requirement must either be certified by a registered professional engineer or architect, or meet or exceed the following minimum criteria:
         A.   A minimum of two openings having a net total area of not less than one square inch for every square foot of enclosed space.
         B.   The bottom of all openings shall be no higher than one foot above grade.
         C.   Openings may be equipped with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.
   (g)   Historic Structures. Historic structures undergoing repair or rehabilitation that would constitute a substantial improvement as defined in this chapter, must comply with all ordinance requirements that do not preclude the structure's continued designation as a historic structure. Documentation that a specific ordinance requirement will cause removal of the structure from the National Register of Historic Places or the State Inventory of Historic places must be obtained from the Secretary of the Interior or the State Historic Preservation Officer. Any exemption from ordinance requirements will be the minimum necessary to preserve the historic character and design of the structure.
   (h)   OPTIONAL: Accessory Structures. Structures accessory to a principal building need not be elevated or floodproofed to remain dry, but shall comply, at a minimum, with the following requirements:
      (1)   The structure shall not be designed or used for human habitation, but shall be limited to the parking of vehicles, or to the storage of tools, material, and equipment related to the principal use or activity.
      (2)   Floor area shall not exceed 200 square feet.
      (3)   The structure will have a low damage potential.
      (4)   The structure will be located on the site so as to cause the least obstruction to the flow of flood waters.
      (5)   Power lines, wiring, and outlets will be elevated to the regulatory flood elevation.
      (6)   Permanently affixed utility equipment and appliances such as furnaces, heaters, washers, dryers, etc. are prohibited.
      (7)   Sanitary facilities are prohibited.
      (8)   The structure shall be adequately anchored to prevent flotation, collapse, and lateral movement and shall be designed to automatically provide for the entry and exit of floodwater for the purpose of equalizing hydrostatic forces on the walls. Designs for meeting this requirement must either be certified by a registered professional engineer or architect, or meet or exceed the following minimum criteria:
         A.   A minimum of two openings having a net total area of not less than one square inch for every square foot of enclosed space.
         B.   The bottom of all openings shall be no higher than one foot above grade.
         C.   Openings may be equipped with screens, louvers, etc. or other coverings or devices provided that they permit the automatic entry and exit of flood waters.
(Ord. 02-14. Passed 6-19-14.)