§ 52.18 PERMIT ISSUANCE CONDITIONS IN COMBINED SEWER AREAS.
   No permits for sewers shall be issued by the Village unless the following conditions in all areas designated as combined sewer areas on the metro- politan sanitary district maps are complied with:
   (A)   Separation. Complete separation of sewers shall be provided within the property lines.
   (B)   Downspouts. All downspouts or roof drains shall discharge onto the ground or be connected to a storm sewer. No downspouts or roof drains shall be connected to the sanitary sewers.
   (C)   Footing drains. Footing drains shall be connected to sump pumps and discharge shall be made into storm sewers or drainage ditches. No footing drains or drainage tile shall be connected to the sanitary sewer.
   (D)   Sump pumps.
      (1)   Sump pumps installed to receive and discharge groundwaters or other storm waters shall be connected to a storm sewer or discharge into a drainage ditch.
      (2)   Sump pumps installed to receive and discharge floor drain flow or other sanitary sewage shall be connected to the sanitary or combined sewers.
      (3)   A sump pump shall be used for one function only, either the discharge of storm water or the discharge of sanitary sewage.
('73 Code, § 32-20) (Ord. 71-983, passed 5-20-71)