25.02.31: AMENDMENT OF SECTION 1905.1 AND ADDITION OF SECTIONS 1905.1.9 AND 1905.1.10:
Notwithstanding the provisions of section 25.02.01 of this article, section 1905.1 is amended and sections 1905.1.9 and 1905.1.10 are added to the Building Code to read as follows:
   1905.1 General. The text of ACI 318 shall be modified as indicated in Sections 1905.1 through 1905.1.8
   1905.1.9 ACI 318, Section 21.6.4. Modify ACI 318, Section 21.6.4, by adding Section 21.6.4.8 and 12.6.4.9 as follows:
      21.6.4.8 Where the calculated point of contraflexure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318 Sections 21.6.4.1, Items (a) through (c), over the full height of the member.
      21.6.4.9 - At any section where the design strength, Pn, of the column is less than the sum of the shears Ve computed in accordance with ACI 318 Sections 21.5.4.1 and 21.6.5.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in ACI 318 Sections 21.6.4.1 through 21.6.4.3 shall be provided. For beams framing into opposite sides of the column, the moment components are permitted to be assumed to be of opposite sign. For the determination of the design strength, Pn, of the column, these moments are permitted to be assumed to result from the deformation of the frame in any one principal axis.
   1905.1.10 ACI 318, Section 21.9.4. Modify ACI 318, Section 21.9.4, by adding Section 21.9.4.6 as follows:
      21.9.4.6 - Walls and portions of walls with Pu > 0.35Po shall not be considered to contribute to the calculated shear strength of the structure for resisting earthquake-induced forces. Such walls shall conform to the requirements of ACI 318 Section 21.13.
(Ord. 0-19-1357, 11-13-2019)