Notwithstanding the provisions of section 25.03.01 of this article, table R602.10.5 of the Residential Code is amended to read as follows:
TABLE R602.10.5
MINIMUM LENGTH OF BRACED WALL PANELS
METHOD (See Table R602.10.4)
| MINIMUM LENGTHa
(inches)
|
CONTRIBUTING LENGTH (inches)
| |||||
Wall Height
| |||||||
8 feet
|
9 feet
|
10 feet
|
11 feet
|
12 feet
|
METHOD (See Table R602.10.4)
| MINIMUM LENGTHa
(inches)
|
CONTRIBUTING LENGTH (inches)
| |||||
Wall Height
| |||||||
8 feet
|
9 feet
|
10 feet
|
11 feet
|
12 feet
| |||
DWB, WSP, SFB, PBS, PCP, HPS, BV - WSP | 48 | 48 | 48 | 53 | 58 | Actualb | |
GB | 48 | 48 | 48 | 53 | 58 | Double sides = Actual Single sided = 0.5 x Actual | |
LIB | 55 | 62 | 69 | NP | NP | Actualb | |
ABW | SDC A, B and C, wind speed < 110 mph | 28 | 32 | 34 | 38 | 42 | 48 |
SDC D0, D1 and D2 wind speed < 110 mph | 32 | 32 | 34 | NP | NP | ||
PFH | Supporting roof only | 24 | 24 | 24 | 24c | 24c | 48 |
Supporting one story and roof | 24 | 24 | 24 | 27c | 29c | 48 | |
PFG | 24 | 27 | 30 | 33d | 36d | 1.5 x Actualb | |
CS-G | 24 | 27 | 30 | 33 | 36 | Actualb | |
CS-PF | 24 | 24 | 24 | 24e | 24e | Actualb | |
CS- WSP, CS-SFB | Adjacent clear opening height (inches) | ||||||
< 64 | 24 | 27 | 30 | 33 | 36 | Actualb | |
68 | 26 | 27 | 30 | 33 | 36 | ||
72 | 27 | 27 | 30 | 33 | 36 | ||
76 | 30 | 29 | 30 | 33 | 36 | ||
80 | 32 | 30 | 30 | 33 | 36 | ||
84 | 35 | 32 | 32 | 33 | 36 | ||
88 | 38 | 35 | 33 | 33 | 36 | ||
92 | 43 | 37 | 35 | 35 | 36 | ||
96 | 48 | 41 | 38 | 36 | 36 | ||
100 | – | 44 | 40 | 38 | 38 | ||
104 | – | 49 | 43 | 40 | 39 | ||
108 | – | 54 | 46 | 43 | 41 | ||
112 | – | – | 50 | 45 | 43 | ||
116 | – | – | 55 | 48 | 45 | ||
120 | – | – | 60 | 52 | 48 | ||
124 | – | – | – | 56 | 51 | ||
128 | – | – | – | 61 | 54 | ||
132 | – | – | – | 66 | 58 | ||
136 | – | – | – | – | 62 | ||
140 | – | – | – | – | 66 | ||
144 | – | – | – | – | 72 | ||
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, I mile per hour=Q.447 m/s. NP = Not Permitted.
a. Linear interpolation shall be permitted.
b. Use the actual length when it is greater than or equal lo the minimum length.
c. Maximum header height for PFH is 10 feet in accordance with Figure R602.10.6.2, but wall height may be increased to 12 feet with pony wall.
d. Maximum opening height for PFG is 10 feet in accordance with Figure R602.10.6.3. but wall height maybe increased to 12 feet with pony wall,
e. Maximum opening height for CS-PF is 10 feet in accordance with Figure R602.10.6.4. but wall height may be increased to 12 feet with pony wall.
(Ord. 0-19-1357, 11-13-2019)