In the Medical Facilities Zone, the setback distance from Las Tunas Drive shall be zero (0') feet. The setback distance from all other streets in the zone shall be five (51) feet. The minimum setback distance from any interior side or rear property line when adjoining R-1 zones shall be ten (101) feet, plus five (51) feet for each ten (101) feet or fraction thereof, of gross building height in excess of thirty (301) feet. The minimum setback distance from any interior side or rear property line when adjoining R-3 zones shall be ten (101) feet, plus two (21) feet for each ten (101) feet or fraction thereof, of gross building height in excess of thirty (301) feet. The minimum setback distance from any interior or rear property line when adjoining Medical Facilities or C-1 zones shall be zero (01) feet.
Additionally, buildings with a gross building height in excess of forty (401) feet when adjoining R-1 zones, shall be stepped back from the setback distance required above as follows:
Any portion of the building between
41' - 50' in height 10'
51' - 60' in height 20'
61' - 70' in height 30'
(Ord. 491-C.S., passed 10-6-98)