§ 153.155 DEVELOPMENT STANDARDS.
   The table below identifies the development standards applicable to all development in the C-1, C-3, and M-1 zones.
 
Development Standards
Zone District
Notes
C-1
C-3
M-1
Minimum lot size
None
None
None
See § 153.162 regarding automobile service stations and hotel/motels
Minimum lot width
50 feet
50 feet
50 feet
Maximum building height
5 stories/ 70 ft., whichever is lower
5 stories/ 70 ft., whichever is lower
2 stories/ 35 ft., whichever is lower
An additional 10 ft. allowed to enclose elevator tower or fire stairway. See also § 153.157
Front yard
0 feet
0 feet
0 feet
a. Front setback may be required through precise plan of design review or CUP
 
b. See § 153.162 regarding automobile service stations
Side yard:
 
Abutting C-1, C-3, or M-1
 
Abutting any other zone district
0 feet
5 feet
0 feet
10 feet
0 feet
10 feet
See § 153.162 regarding automobile service stations
 
 
Development Standards
Zone District
Notes
C-1
C-3
M-1
Rear yard:
 
Abutting C-1, C-3, or M-1
 
Abutting any other zone district
10 feet
10 feet
10 feet
15 feet
15 feet
20 feet
Structures may locate on rear property line abutting C-1, C-3, and M-1 where structure is of solid masonry construction and no windows, doors, or other openings are on the wall located on the property line
Maximum floor area ration
0.5
0.7
0.5
FAR may be increased for mixed-use development in C-3 zone; see § 153.164
Distance between buildings
As required by Fire Code
As required by Fire Code
As required by Fire Code
 
('65 Code, § 9-3.820) (Ord. 455-C.S., passed 11-21-95)