The water and sanitation provisions in Table 83-11 shall be met for proposed subdivisions created by Parcel Map in the Desert Region unless the following standards can be met:
(a) Wells shall be setback from all leach lines by 100 feet and from seepage pits by 150 feet.
(b) Wells shall be set back from all property lines where no leach lines exist on the adjacent property by 50 feet.
(c) Septic systems with leach lines shall be setback from all wells by 100 feet.
(d) Septic systems with leach lines shall be setback from property lines where no leach lines exist on the adjacent property by 50 feet.
(e) Septic systems with seepage pits shall be setback from all wells by 150 feet.
(f) Septic systems with seepage pits shall be setback from property lines where no leach lines exist on the adjacent property by 75 feet.
(g) Applicants providing a preliminary Composite Development Plan showing the envelope locations of the building/house pad, septic tanks/pits/leach fields, and water well do not have to meet these requirements for the requirements listed above when supporting engineering data is provided demonstrating feasibility of septic systems and wells. The location will be denoted on the final Composite Development Plan that accompanies a Final Map or Parcel Map.
(Ord. 4011, passed - -2007)