SECTION 1016 – EXIT ACCESS
1016.2  Add item 7 as follows:
   7.   [Reference CRC R311.1] For one- and two-family dwellings and townhouses, means of egress is allowed to pass through rooms and intervening spaces except garages.
(Amended by Ord. 65-19, File No. 190136, App. 4/12/2019, Eff. 5/13/2019)
1016.3  Add a section as follows:
1016.3  [Reference CRC R311.4]  Vertical egress.  For habitable levels or basements in R-3 occupancies or townhouses that are located more than one story above or more than one story below an egress door, the maximum travel distance from any occupied point to a stairway or ramp that provides egress from such habitable level or basement shall not exceed 50 feet (15240 mm).