The following pollutant limits are established to protect against pass through and interference.
(A) Conventional pollutants; guidelines for discharge. The guidelines listed below are daily maximum limits.
(1) No user should discharge any wastewater containing concentrations greater than the guidelines as set forth below into any sewers that connect either directly or indirectly to the POTW works.
POLLUTANT | CONCENTRATION |
Ammonia Nitrogen | 50.0 mg/l |
BOD | 300.0 mg/l |
Color | 400 ADMI |
FOG | 100.0 mg/l |
Total Surfactants | 250.0 mg/l |
TSS | 350.0 mg/l |
(B) Toxic pollutants; reserved.
(C) The village reserves the right to establish, by ordinance or in a wastewater discharge permit, mass limitations rather than concentration limitations on discharges.
(Ord. 04-0108, passed 1-21-04; Am. Ord. 07-0563, passed 7-18-07)