§ 154.555 NOISE.
   The following requirements shall apply in all Districts:
   (A)   The sound pressure level, to be measured as described below, shall not exceed the following decibel levels in the designated octave bands when adjacent to the designated types of use districts:
Octave Band, Cycles per Second
Districts
B-1, B-2, B-3
Sound Level in Decibels
All Residential
Octave Band, Cycles per Second
Districts
B-1, B-2, B-3
Sound Level in Decibels
All Residential
0 to 75
73
58
76 to 150
69
54
151 to 300
65
50
301 to 600
61
46
601 to 1,200
55
40
1,201 to 2,400
48
33
2,400 to 4,800
41
26
Over 4,800
35
20
 
   (B)   Objectionable sounds of an intermittent nature which are not easily measured shall be controlled so as not to become a nuisance to adjacent uses.
   (C)   (1)   Measurement is to be made at the nearest boundary of the nearest residential area or at any other point along the boundary where the level is higher.
      (2)   The sound levels shall be measured with a sound level meter and associated octave band filter as prescribed by the American Standards Association.
(Ord. passed 5-16-2023)