In all RMF-2 Multiple-Family Residence Districts the minimum distance between any two buildings shall be regulated according to the length and height of such buildings.
The formula regulating the required minimum distance between two buildings (referred to as building "A" and building "B") is as follows: S = LA + LB + 2 (HA + HB) WHERE 4 S = required minimum horizontal distance between any wall of building A and any wall of building B or the vertical prolongation of either. LA = total length of building A. The total length of building A is the length of that portion or portions of a wall or walls of building A from which, when viewed directly from above, lines drawn perpendicular to building A will intersect any wall of building B. LB = total length of building B. The total length of building B is the length of that portion or portions of a wall or walls of building B from which, when viewed directly from above, lines drawn perpendicular to building B will intersect any wall of building A. HA = height of building A. The height of building A at any given level is the height above natural grade level of any portion or portions of a wall or walls along the length of building A. Natural grade level shall be the mean level of the ground immediately adjoining the portion or portions of the wall or walls along the total length of the building. HB = height of building B. The height of building B at any given level is the height above natural grade level of any portion or portions of a wall or walls along the length of building B. Natural grade level shall be the mean level of the ground immediately adjoining the portion or portions of the wall or walls along the total length of the building. (Ord. 72-72. Passed 8-31-72.) |