1349.07 LIGHT, VENTILATION AND OCCUPANCY LIMITATIONS.
   (a)   GENERAL.
      (1)    Scope. The provisions of this chapter shall govern the minimum conditions and standards for light, ventilation and space for occupying a structure.
      (2)    Responsibility. The owner of the structure shall provide and maintain light, ventilation and space conditions in compliance with these requirements. A person shall not occupy as owner-occupant, or permit another person to occupy, any premises that do not comply with the requirements of this chapter.
      (3)    Alternative devices. (amended) In lieu of the means for natural light and ventilation herein prescribed, artificial light or mechanical ventilation complying with the Ohio Building Code and the Residential Code of Ohio shall be permitted.
 
   (b)   LIGHT.
      (1)    Habitable spaces. Every habitable space shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be 8 percent of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than 3 feet (914 mm) from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room.
         Exception: Where natural light for rooms or spaces without exterior glazing areas is provided through an adjoining room, the unobstructed opening to the adjoining room shall be at least 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.33m2). The exterior glazing area shall be based on the total floor area being served.
      (2)    Common halls and stairways. Every common hall and stairway in residential occupancies, other than in one- and two family dwellings, shall be lighted at all times with at least a 60-watt standard incandescent light bulb for each 200 square feet (19 m2) of floor area or equivalent illumination, provided that the spacing between lights shall not be greater than 30 feet (9144 mm). In other than residential occupancies, means of egress, including exterior means of egress stairways shall be illuminated at all times. The building space served by the means of egress is occupied with a minimum of 1 footcandle (11 lux) at floors, landings and treads.
      (3)    Other spaces. All other spaces shall be provided with natural or artificial light sufficient to permit the maintenance of sanitary conditions, and the safe occupancy of the space and utilization of the appliances, equipment and fixtures.
 
   (c)   VENTILATION.
      (1)    Habitable spaces. Every habitable space shall have at least one openable window. The total openable area of the window in every room shall be equal to at least 45 percent of the minimum glazed area required in Section 402.1.
         Exception: Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be at least 8 percent of the floor area of the interior room or space, but not less than 25 square feet (2.33m2). The ventilation openings to the outdoors shall be based on a total floor area being ventilated.
      (2)    Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated.
      (3)    Cooking facilities. Unless approved through the certificate of occupancy, cooking shall not be permitted in any rooming unit or dormitory unit, and a cooking facility or appliance shall not be permitted to be present in a rooming unit or dormitory unit.
         Exception: Where specifically approved in writing by the code official.
      (4)    Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space.
      (5)    Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted in accordance with the manufacturer's instructions.
 
   (d)   OCCUPANCY LIMITATIONS.
      (1)    Privacy. Dwelling units, hotel units, housekeeping units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces.
         A.   Communication system. (added) All multiple family dwelling shall be equipped with a two-way communication system for all entrances and exits.
      (2)   Minimum room widths. A habitable room, other than a kitchen, shall not be less than 7 feet (2134 mm) in any plan dimension. Kitchens shall have a clear passageway of not less than 3 feet (914 mm) between counterfronts and appliances or counterfronts and walls.
      (3)    Minimum ceiling heights. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than 7 feet (2134 mm).
         Exceptions: 
         A.   In one- and two-family dwellings, beams or girders spaced not less than 4 feet (1219 mm) on center and projecting not more than 6 inches (152 mm) below the required ceiling height.
         B.   Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a ceiling height of not less than 6 feet 8 inches (2033 mm) with not less than 6 feet 4 inches (1932 mm) of clear height under beams, girders, ducts and similar obstructions.
         C.   Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a clear ceiling height of at least 7 feet (2134 mm) over not less than one-third of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of 5 feet (1524 mm) or more shall be included.
      (4)   Bedroom requirements. Every bedroom shall comply with the requirements of Sections 404.4.1 through 404.4.6 and 404.5.
         A.   Area for sleeping purposes. Every bedroom occupied by one person shall contain at least 70 square feet (6.5 m2) of floor area, and every bedroom occupied by more than one person shall contain at least 50 square feet (4.6 m2) of floor area for each occupant thereof.
         B.   Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces.
            Exception: Units that contain fewer than two bedrooms.
         C.   Water closet accessibility. Every bedroom shall have access to at least one water closet and one lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to at least one water closet and lavatory located in the same story as the bedroom or an adjacent story.
         D.   Prohibited occupancy. Kitchens and non-habitable spaces shall not be used for sleeping purposes.
         E.   Basement bedrooms. (added) Bedrooms and rooms for sleeping purposes shall be prohibited in basements and spaces below grade.
            Exceptions:
            1.    There shall be a direct means of egress stairway meeting the requirements of the adopted building code from the basement area or area below finished grade to the exterior of the structure.
            2.    There shall be a window in the bedroom or room used for sleeping purposes meeting the emergency egress requirements for location, height and area as described in the adopted building code.
         F.   Other requirements. Bedrooms shall comply with the applicable provisions of this code including, but not limited to, the light, ventilation, room area, ceiling height and room width requirements of this chapter; the plumbing facilities and water-heating facilities requirements of Chapter 5; the heating facilities and electrical receptacle requirements of Chapter 6; and the smoke detector and emergency escape requirements of Chapter 7.
      (5)    TABLE MINIMUM AREA REQUIREMENTS (deleted)
      (6)    Food preparation. (amended) All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and refuse, including facilities for temporary storage.
      (7)    Third floor occupancy. (added) All third floor rooms certified for occupancy in a detached single family dwelling shall maintain an exterior stairway meeting the requirements of the adopted building code from such third floor to finished grade.