15.13.100 IRC Chapter 3, Section R303.1 Habitable rooms–Amended.
   IRC Chapter 3, Section R303.1 Habitable rooms is hereby amended to read in its entirety as follows:
   R303.1 Habitable rooms. All habitable rooms shall have an aggregate glazing area of not less than 6 percent of the floor area of such rooms. Natural ventilation shall be through windows, doors, louvers or other approved openings to the outdoor air. Such openings shall be provided with ready access or shall otherwise be readily controllable by the building occupants. The minimum openable area to the outdoors shall be 3 percent of the floor area being ventilated.
      Exceptions:
      1.   The glazed areas need not be openable where the opening is not required by Section R310 and an approved mechanical ventilation system capable of producing 0.35 air change per hour in the room is installed or a whole-house mechanical ventilation system is installed capable of supplying outdoor ventilation air of 15 cubic feet per minute (cfm) (78 L/s) per occupant computed on the basis of two occupants for the first bedroom and one occupant for each additional bedroom.
      2.   The glazed areas need not be installed in rooms where Exception 1 above is satisfied and artificial light is provided capable of producing an average illumination of 6 foot candles (65 lux) over the area of the room at a height of 30 inches (762 mm) above the floor level.
      3.   Use of sunroom additions and patio covers, as defined in Section R202, shall be permitted for natural ventilation if in excess of 40 percent of the exterior sunroom walls are open, or are enclosed only by insect screening.
      4.   Media and theater rooms.
(Ord. 6270 (part), 2019: Ord. 6009 (part), 2015: Ord. 5891 (part), 2013: Ord. 5819 (part), 2012)