§ 51.20 SIZE REQUIREMENTS FOR PUBLIC SEWER AND SERVICE LATERALS.
   (A)   Gravity public sewers shall be eight inches in diameter, or larger, to be accepted as part of the town’s wastewater collection system, except as provided in division (B) below.
   (B)   Six-inch diameter public sewers will be accepted as part of the town’s wastewater collection system when:
      (1)   The sewer serves only a small restricted area and is designed so that it cannot be extended to serve any additional area;
      (2)   The service does not exceed 250 feet in length; or
      (3)   A manhole is located at the upstream terminus of the sewer.
   (C)   The minimum size of a service lateral connecting to a public sewer shall be four inches in diameter.
(Prior Code, § 16-1-5) (Ord. 91-02, passed - -1991; Ord. 91-04, passed - -1991; Res. 91-09, passed - -1991; Ord. 92-04, passed - -1992; Res. 92-04, passed - -1992; Res. 94-22, passed - -1994; Ord. 00-04, passed - -2000; Ord. 10-01, passed - -2010)