A. Table Of Regulations: The lot and building regulations of table 2-2 of this section apply to all principal uses and structures in R Districts, except as otherwise expressly stated in this UDO. General exceptions to these regulations and rules for measuring compliance can be found in chapter 19 of this title. Regulations governing accessory uses and structures can be found in chapter 8 of this title.
Regulations | RS-70 | RS-50 | RS-35 | RD | RT | RM | RMH |
Regulations | RS-70 | RS-50 | RS-35 | RD | RT | RM | RMH | |
Minimum lot area (sq. ft.): | ||||||||
Detached house | 8,400 | 6,000 | 4,000 | 6,000 | 6,000 | 6,000 | 5,500 | |
Patio house (see also section 10-7-10 of this title) | n/a | n/a | 4,000 | 6,000 | 4,000 | 4,000 | 5,500 | |
Townhouse (see also section 10-7-12 of this title) | n/a | n/a | n/a | n/a | 2,200 | 2,200 | n/a | |
Duplex | n/a | n/a | n/a | 6,000 | 6,000 | 6,000 | n/a | |
Multi-unit house (see also section 10-7-9 of this title) | n/a | n/a | n/a | n/a | 8,000 | 8,000 | n/a | |
Apartment/condo | n/a | n/a | n/a | n/a | n/a | 10,000 | n/a | |
Mobile home/ mobile home park | n/a | n/a | n/a | n/a | n/a | n/a | See section 10-7-8 of this title | |
Other allowed buildings/uses | 12,000 | 10,000 | 10,000 | 10,000 | 10,000 | 10,000 | 10,000 | |
Minimum lot area per unit (sq. ft.): | ||||||||
Detached house | 8,400 | 6,000 | 4,000 | 6,000 | 6,000 | 6,000 | 4,000 | |
Patio house (see also section 10-7-10 of this title) | n/a | n/a | 4,000 | 6,000 | 4,000 | 4,000 | 4,000 | |
Townhouse (see also section 10-7-12 of this title) | n/a | n/a | n/a | n/a | 2,200 | 2,200 | n/a | |
Duplex | n/a | n/a | n/a | 3,000 | 3,000 | 3,000 | n/a | |
Multi-unit house (see also section 10-7-9 of this title) | n/a | n/a | n/a | n/a | 2,000 | 2,000 | n/a | |
Apartment/condo | n/a | n/a | n/a | n/a | n/a | 2,800 | n/a | |
Minimum lot width (feet): | ||||||||
Detached house | 70 | 50 | 35 | 50 | 50 | 50 | 50 | |
Patio house (see also section 10-7-10 of this title) | n/a | n/a | 35 | 35 | 35 | 35 | 50 | |
Townhouse (see also section 10-7-12 of this title) | n/a | n/a | n/a | n/a | 20 | 20 | n/a | |
Duplex | n/a | n/a | n/a | n/a | 70 | 50 | n/a | |
Multi-unit house (see also section 10-7-9 of this title) | n/a | n/a | n/a | n/a | 70 | 50 | n/a | |
Apartment/condo | n/a | n/a | n/a | n/a | n/a | 100 | n/a | |
Other allowed buildings/uses | 110 | 100 | 100 | 100 | 100 | 100 | 100 | |
Minimum building setbacks: | ||||||||
Front (feet) | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
Street side (feet) | 15 | 15 | 15 | 15 | 15 | 15 | 15 | |
Interior side (feet) | 10/151 | 101,2 | 101,2,3 | 101,2 | 101,2,3,4 | 101,2 | 101,2 | |
Rear (% of lot depth) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Maximum building coverage (% of lot) | 30 | 35 | 35 | 35 | 35 | 50 | 30 | |
Maximum building height (feet) | 35 | 35 | 35 | 35 | 35 | 35 | 35 | |
Notes:
1. The minimum required interior side setback for principal buildings occupied by nonresidential uses is 15 feet or the height of the building, whichever is greater.
2. Minimum interior side setback is reduced to 5 feet for single-story residential dwellings.
3. See section 10-7-10 of this title for setback regulations applicable to patio houses.
4. No side setback is required for interior units in townhouse developments. Side setback applies to end units (see figure 2-1 of this section).
(Ord. 2018-16, 12-4-2018)