925.15 MATERIALS SPECIFICATIONS; PIPE AND JOINTS.
   Materials used in the construction of building sewers shall be first class, free from defects, with a minimum diameter of five inches. The following materials are approved by the Department of Engineering for building sewers.
   (a)   Salt-glazed vitrified clay pipe.
   (b)   Ceramic-glazed vitrified clay pipe.
   (c)   Cast-iron soil pipe.
   (d)   Unglazed vitrified clay tile.
   (e)   Type PSP (Poly Vinyl Chloride) PVC A.S.T.M. D-3033-74.
   (f)   Type PSM (Poly Vinyl Chloride) PVC A.S.T.M. D-3034-74.
   (g)   Type ABS (Acrylonitrile-Butadiene-Styrene) A.S.T.M. D-2751-73.
   (h)   Type ABX (Acrylonitrile-Butadiene-Styrene) A.S.T.M. D-2680-74.
   On vitrified clay pipe only, prefabricated joints, such as Ty-lox, Wedge-lox, Am-Vit or their approved equal shall be used. No mortar joints or slip-seal joints shall be allowed. Joints of cast-iron soil pipe shall be made with oakum and lead.
   Curved pipe shall be used in all angles in the building sewer greater than three inches deviation from a straight line in the length of one joint of pipe.