For the purpose of this subchapter, the following definition shall apply unless the context clearly indicates or requires a different meaning.
AIR GAP SEPARATION. The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle. An approved air gap shall be at least double the diameter of the supply pipe, measured vertically, above the top of the rim of the receptacle and in no case less than one inch.
ANTI-SIPHON VACUUM BREAKER. A device which restricts the backflow of water into a potable water system by a simple check valve. The vacuum is broken by allowing air to enter upstream of the check valve.
APPROVED. A backflow prevention device or method has been accepted by the Superintendent as being suitable for the intended use.
AUXILIARY WATER SYSTEM. Any water supply system available to the premises other than the public water supply system, and includes the water supplied by such system. These AUXILIARY WATER SYSTEMS may include water from another owner’s public water supply system, polluted or contaminated water, process fluids, used water or other sources of water over which the city does not have sanitary control.
BACKFLOW or BACKSIPHONAGE. The flow of water or other liquids, mixtures or substances into the water distribution system from any other source than the intended source of the potable water supply.
CONSUMER. The owner or person in control of any premises supplied by or in any manner connected to a public water supply system.
CONSUMER’S WATER SUPPLY SYSTEM. Any water supply system located on the consumer’s premises supplied by or in any manner connected to a public water supply system. A household plumbing system is considered to be a CONSUMER’S WATER SUPPLY SYSTEM. A fire suppression system is also considered a CONSUMER’S WATER SUPPLY SYSTEM.
CONTAMINATION. An impairment of the quality of the water by sewage or waste to a degree which could cause an actual hazard to the public health through poisoning or through the spread of disease by exposure.
CROSS-CONNECTION. Any arrangement whereby contamination due to backflow or backsiphonage can occur.
DEGREE OF HAZARD. A term derived from an evaluation of the potential risk to health and the adverse effects upon the potable water system.
DOUBLE CHECK VALVE ASSEMBLY. An assembly composed of two single, independently acting check valves, including 100% closing shutoff ball valves located at each end of the assembly and suitable connections for testing the water tightness of each check valve.
HEALTH HAZARD. Any condition, device or practice in a water system or its operation that creates a real or potential danger to the health and well being of the consumer.
INTERCHANGEABLE CONNECTION. An arrangement or device that will allow alternate but not simultaneous uses of two sources of water.
LICENSED PLUMBER. A person who has obtained approval from the Mayor and City Council to perform plumbing-related work within the city limits. A list of approved plumbers shall be kept by the City Administrator.
NON-POTABLE WATER. Water not safe for drinking, personal or culinary use, or which does not meet the requirements of the state’s Department of Health.
OWNER. The entity delivering water through a public water supply system. The OWNER is the City of Ponca.
PLUMBING HAZARD. A plumbing-type cross-connection in a consumer’s potable water system that has not been properly protected by air gap separation or backflow prevention devices.
POLLUTION. The presence in water of any foreign substances (organic, inorganic or biological) that degrade the quality of water to a degree which does not necessarily cause an actual hazard to the public health but which does adversely and unreasonably affect such waters for any desired use.
POTABLE WATER. Water which is satisfactory for drinking, culinary and domestic purposes and meets the requirements of the state’s Department of Health.
PUBLIC WATER SUPPLY SYSTEM. A water supply system designed and intended to provide potable water to a designated consumer. The WATER SUPPLY shall include the water supply source and distribution piping network. WATER SUPPLY SOURCE is defined as any artificial or natural accumulation of water used to supply the potable water system. The DISTRIBUTION PIPING NETWORK includes all piping, pumping and treatment devices used to convey an adequate quality and quantity of potable water to the consumer.
REDUCED PRESSURE ZONE BACKFLOW PREVENTION DEVICE. A device containing a minimum of two independently acting check valves together with an automatically operated pressure differential relief valve located between two check valves. During normal flow and at the cessation of normal flow, the pressure between these two checks shall be less than the supply pressure. In case of leakage of either check valve, the differential relief valve, by discharging to the atmosphere, shall operate to maintain the pressure between the check valves at less than the supply pressure. The unit must include 100% closing shutoff ball valves located at each end of the device, and each device shall be fitted with properly located test cocks.
SERVICE CONNECTION. The terminal end of a service line from the public water system. If a meter is installed at the end of the service line, then the service connection means the downstream end of the meter.
SYSTEM HAZARD. A condition posing an actual or potential threat of damage to the physical properties of the public’s or the consumer’s water supply system.
USED WATER. Any water supplied by the public water supply system to a consumer’s water supply system after it has passed through the service connection and is no longer under the sanitary control of the water supplier.
(Prior Code, § 6-126)