§ 2.9B DEVELOPMENT STANDARDS.
      (1)   Minimum lot width and frontage. Each lot or integrated center shall have a minimum lot width and frontage on a public street of 50 feet.
      (2)   Minimum yards and building setbacks.
         (a)   Front. A minimum front yard and building setback measured from the proposed right-of-way shall be provided as follows:
 
Collector street
30 ft.
Interstate street
60 ft.
Local street/cul-de-sac street
30 ft.
Primary arterial street
30 ft.
Secondary arterial street
30 ft.
 
         (b)   Minimum side yard and setback. Shall be provided from the lot line as follows:
 
Minimum side bufferyard
15 ft.
Minimum side yard
10 ft.
 
         (c)   Minimum rear yard and setback. Shall be provided from the lot line as follows:
 
Minimum rear yard
10 ft.
Minimum rear bufferyard
15 ft.
 
         (d)   Minimum yards for out lots. Out lots within an integrated center shall provide a minimum yard of five feet along all lot lines in common with other out lots or with the main portion of the integrated center. If any portion of an out lot abuts the perimeter of the integrated center, that portion of the out lot shall be required to comply with the applicable minimum front, side or rear yard requirements set forth above. The main portion of the integrated center shall not be required to provide a minimum yard along the lot line in common with an out lot.
      (3)   Use of minimum yards and bufferyards. All minimum yards and bufferyards shall be landscaped with grass, trees, shrubbery or hedge, or in combination with other suitable ground cover materials and shall remain free from structures except where expressly permitted below:
         (a)   Minimum front yards. May include driveways and parking areas (provided that no portion of the parking area may be located closer to the right-of-way than ten feet; except for minimum front yards abutting the Ronald Reagan Parkway or a frontage street parallel to the Ronald Reagan Parkway, where parking areas shall be prohibited) and shall be maintained as open space free from buildings or structures in compliance with the requirements for perimeter landscape yards as set forth in Article IV;
         (b)   Minimum front bufferyards. May include driveways and shall be maintained as open space free from buildings or structures in compliance with the requirements for perimeter landscape yards as set forth in Article IV;
         (c)   Minimum side and rear yards. Minimum side and rear yards may include interior access driveways connecting to adjoining lots provided that the remainder of said yards shall be maintained as open space free from buildings or structures in compliance with the requirements for perimeter landscape yards as set forth in Article IV; and
         (d)   Minimum side and rear bufferyards. Shall be landscaped with grass and shrubbery, trees or hedge, or in combination with other suitable ground cover materials and maintained in compliance with the requirements for perimeter landscape yards as set forth in Article IV.
      (4)   Maximum building height. 35 feet.
      (5)   Parking and loading. See Article IV.
      (6)   Signs. See Article VII.
      (7)   Outdoor operations. All uses and operations (except off-street parking, off-street loading and delivery, walk-up customer service windows and drive-through customer service windows) shall be conducted completely within enclosed buildings, except where expressly permitted below:
         (a)   Outdoor seating shall not be located between a building line and a bufferyard;
         (b)   Vending machines, provided that vending machines:
            1.   Shall abut the exterior wall of the building; and
            2.   Shall not be located in a required yard or required bufferyard.
         (c)   Outdoor display or sales, provided that such display or sales shall:
            1.   Be accessory to the primary use;
            2.   Not exceed 1% of the gross floor area of each non-related and separately operated use;
            3.   Shall not be located in a required yard or required bufferyard; and
            4.   Shall not be located so as to interfere or conflict with walks, required parking areas, required loading areas, driveways, interior access drives, interior access driveways, perimeter landscape yards or foundation plantings.
         (d)   Gasoline pumps, provided that no outdoor operations other than the dispensing or installation of gasoline, oil, antifreeze and other similar products and the performance of minor services for customers as related to said dispensing or installation are conducted on the site.
      (8)   Landscape requirements. See Article IV.
      (9)   Maximum gross floor area.
         (a)   No single use, whether freestanding or contained in an integrated center, shall exceed 8,000 square feet of gross floor area.
         (b)   No integrated center shall exceed 24,000 square feet of total gross floor area.
(Ord. 21-97, passed - -1997; Ord. 39-2006, passed 10-9-2006; Ord. 27-2007, passed - -2007; Ord. 04-2013, passed 2-25-2013)