715.04 CONDITION OF SYSTEM CONSTRUCTION; MAINTENANCE
       AND OPERATION.
   The operator shall comply with the following conditions:
   (a)    Construction, operation and maintenance of the transmission and distribution system shall be in accordance with the latest edition of the National Electrical Safety Code, also referred to as the Code of the Board of Underwriters, and the ordinance and regulations of the Federal Communications Commission, the State and the Village, that are in effect now or in the future.
   (b)    Each cable operator shall provide for and maintain a system that will transmit or transport the following frequencies:
 
Downstream
50 to 300 MHz
Upstream
5 to 30 MHz
 
   (c)    In operating his system, the operator shall meet the following minimum requirements:
      (1)    The system shall be operated so as to meet or exceed the FCC specifications outlined in the FCC rules and regulations Sub-Part K, Section 76.601, et seq., Technical Standards, or successor rules and regulations. The upstream frequency spectrum shall meet or exceed the FCC standards for downstream frequency.
      (2)    The operator shall be able to demonstrate by instruments or otherwise to subscribers, upon request, that a signal of adequate strength and quality as described in subsection (c)(1) hereof is being delivered by the system.
   (d)    The operator shall provide the Administrator with the name of his chief management employee for the referral of complaints made to the Village.
   (e)    In the case of any emergency or disaster declared by the Administrator, the operator shall, upon request of the Administrator, make available without charge necessary facilities for use by the Village during the emergency or disaster.
      (Ord. 5-80. Passed 5-12-80; Ord. 14-2021. Passed 6-14-21.)