SECTION N1106  ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
Pursuant to the UCC, delete Table N1106.4 and replace as follows with added footnote "a":
TABLE R-N1106.4
MAXIMUM ENERGY RATING INDEX
 
CLIMATE ZONE
ENERGY RATING INDEXa
1
57
2
57
3
57
4
62
5
61
6
61
7
58
8
58
 
a.   Where on-site renewable energy is included for compliance using the ERI analysis of Section N1106.4, the building shall meet the mandatory requirements of N1106.2 and the building thermal envelope shall be greater than or equal to the levels of efficiency and SHGC in Table N1102.1.2 or Table N1102.1.4.