SECTION P-702  MATERIALS 319
P-702.1 Above-ground sanitary drainage and vent pipe. Above-ground soil, waste and vent pipe shall conform to one of the standards listed in Table 702.1. Any above ground soil, waste and vent piping serving or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this Section.
P-702.1.1 High Rise material. Metallic piping shall be installed throughout buildings 75 feet 320 (22 860 mm) or more in height as measured from the lowest level of fire department vehicle access.
*      *      *
P-702.2Underground building sanitary drainage and vent pipe. Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table P-702.2. Any underground building sanitary drainage and vent piping serving or located within occupancies other than one and two family dwellings and apartments shall be metallic piping in accordance with this Section.
Table P-702.2
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall
ASTM D2661; ASTM F628; ASTM F1488; CSA B181.1
Table P-702.2
Cast-iron pipe
ASTM A74; ASTM A888; CISPI 301 321
Table P-702.2
Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall
ASTM D2665; ASTM F891; ASTM F1488; CSA B181.2
Table P-702.2
Polyvinyl chloride (PVC) plastic pipe with a 3.25-inch O.D. and a solid, cellular core or composite wall
ASTM D2949, ASTM F1488
P-702.2.1 High Rise material. Metallic piping shall be installed for all underground building sanitary drainage and vent piping for buildings 75 feet (22 860 mm) or more in height as measured from the lowest level of fire department vehicle access.
P-702.3 Building sewer pipe. Building sewer pipe shall conform to one of the standards listed in Table P-702.3. Any building sewer pipe serving or located within occupancies other than one- and two-family dwellings and apartments shall be metallic piping in accordance with this Section.
Table P-702.3
Cast-iron pipe
ASTM A74; ASTM A888; CISPI 301 322
Table P-702.3
Ductile Iron pipe
AWWA C151/A21.51; AWWA C115/A21.15
Table P-702.3
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall
ASTM D2661; ASTM F628; ASTM F1488; CSA B181.1
Table P-702.3
Acrylonitrile butadiene styrene (ABS) plastic pipe in sewer and drain diameters, including SDR 42 (PS 20), PS 35, SDR 35 (PS 45), PS 50, PS 100, PS 140, SDR 23.5 (PS 150) and PS 200; with a solid, cellular core or composite wall
ASTM F1488; ASTM D2751
Table P-702.3
Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall
ASTM D2665; ASTM F891; ASTM F1488
Table P-702.3
Polyvinyl chloride (PVC)plastic pipe in sewer and drain diameters, including PS 25, SDR 41 (PS 28), PS 35, SDR 35 (PS 46), PS 50, PS 100, SDR 26 (PS 115), PS 140 and PS 200; with a solid, cellular core or composite wall
ASTM F891; ASTM F1488; ASTM D3034; CSA B182.2; CSA B182.4
Table P-702.3
Polyvinyl chloride (PVC) plastic pipe with a 3.25-inch O.D. and a solid, cellular core or composite wall
ASTM D2949; ASTM F1488
P-702.3.1 High Rise material. Metallic piping shall be installed for all building sewer pipe for buildings 75 feet (22 860 mm) or more in height as measured from the lowest level of fire department vehicle access.
P-702.3.2 Lateral. Lateral materials and installation shall be regulated by the Philadelphia Water Department.
*      *      *
P-702.6 Chemical waste system. A chemical waste system shall be completely separated from the sanitary drainage system. The chemical waste shall be treated in accordance with Section 803.2 before discharging to the sanitary drainage system. Separate drainage systems for chemical wastes and vent pipes shall be of an approved material that is resistant to corrosion and degradation for the concentrations of chemicals involved. The restrictions on non- metallic pipe shall not apply to this Section.
702.7 Lead bends and traps. The wall thickness of lead bends shall not be less than 1/8 inch (3.2 mm).
*      *      *

 

Notes

319
   Enrolled bill did not include this Section number or caption; added at the discretion of the Code editor.
320
   Enrolled bill read "P-75 feet".
321
   Amended, Bill No. 190713 (approved December 30, 2019), effective February 3, 2020. See note 313 for effective date provisions.
322
   Amended, Bill No. 190713 (approved December 30, 2019), effective February 3, 2020. See note 313 for effective date provisions.