9-18-6: SITE DESIGN AND INSTALLATION:
   A.   Ground- or pole-mounted solar energy systems shall not exceed 25 feet in height when oriented at maximum tilt. Systems that exceed this height will only be allowed by conditional use permit.
   B.   For rooftop fire safety, required setbacks of 3 feet from roof ridges, and 1.5 feet from valleys and headwalls shall be met to allow fire fighter access.
   C.   Setback distances for ground mounted systems shall be at least 50' from property lines, and 100' from public roads.
   D.   Solar energy systems proposed to be located within 1,000 feet of an airport, within approach zones of an airport, or in an airport or airspace overlay zone will be required to complete and provide the results of the Solar Glare Hazard Analysis Tool (SGHAT).
   E.   Lighting: Any lighting at the solar installation site, either temporary or permanent, shall utilize motion sensors and be directed downward and inward toward the solar installation so as to minimize the glare on public roads and adjacent properties. (Ord. 09-09, 10-6-2009; amd. Res. 20-26, 9-21-2021)