7-3-4-4: CEILING HEIGHT - AIR SPACE - VENTILATION:
   No laundry shall be maintained, conducted, or operated in any room or place in which the clear height between the ceiling and the finished floor is less than ten feet (10'), or which is not ventilated by means of windows, skylights, air shafts, air ducts or mechanical apparatus so that a complete change of air in all parts of such room or place shall be made at least six (6) times per hour.
   Every room in any laundry, (except the room or rooms used for drying purposes) in which the temperature and humidity are such as, in the judgment of the Development Services Department Director, might endanger the health of the person washing therein shall be provided with a mechanical ventilating system approved by said Development Services Department Director.