6-4-3-3: MFG MANUFACTURING DISTRICT:
   In MFG Manufacturing District, at no point either on the boundary of a residence, business or commercial district, or at one hundred twenty five feet (125') from the nearest property line of a plant or operation, whichever distance is greater, shall the sound pressure level of any individual operation or plant, or the combined operations of any person, exceed the decibel levels in the designated octave bands shown below for the zoning districts included as measured under subsection 4 of the TEST PROCEDURES Section of this Chapter:
Octave Band Center
Maximum Sound Pressure Levels
(dB) Along District Boundaries
Frequency (Hz)
Residence
Business- Commercial
31.5
75
80
63
74
79
125
69
74
250
64
69
500
58
63
1,000
52
57
2,000
47
52
4,000
43
48
8,000
40
45
A-scale levels (for monitoring purposes)
61 dB (A)
66 dB (A)