(A) Concrete driveways shall be of a quality as hereinafter stated:
(1) Concrete mix shall be designed using the following data:
(a) Minimum compressive strength of 3500 psi at 28 days;
(b) Minimum of six sacks of cement per cubic yard;
(c) Maximum size aggregate of one inch.
(2) Concrete driveways shall be a minimum thickness of four inches.
(3) Ten-gauge steel mesh is to be required in all concrete driveways in the village.
(B) Expansion joints shall be placed at the junction of the driveway apron and the sidewalk and at the junction of the driveway apron and the curb.
Such expansion joints shall be ½-inch thick pre-molded filler strips with the top of the strip placed ¼-inch below the surface of the driveway apron.
(Ord. 77-23, passed 11-23-77) Penalty, see § 150.999