(a) Every building of the type described below which is hereafter built, relocated or structurally altered to the extent of more than fifty percent (50%) addition in floor area, shall provide off-street truck loading spaces in accordance with the following schedules:
(1) A building whose dominant use is handling and selling goods at retail shall provide such spaces in relation to the floor area used for retail purposes as follows:
Area (sq. ft.) Loading Spaces Required 5,000-10,000 One 10,000-20,000 Two 20,000-30,000 Three Over 30,000 Four |
(2) Manufacturing, repair, wholesale, trucking terminal or warehouse uses shall provide such spaces in relation to total floor area as follows:
Area (sq. ft.) Loading Spaces Required 5,000-40,000 One 40,000-100,000 Two Over 100,000 Three |
(3) Other building not listed above but having over 10,000 square feet in floor area shall provide one such space. This includes offices, hotels and mortuaries.
(b) Every loading space shall have minimum dimensions of not less than twelve feet in width, fifty feet in length, exclusive of driveways, aisles and other circulation areas, and a height of clearance of not less than fifteen feet.
(Ord. 164-1984. Passed 1-28-85.)