6-2-7-4: GARAGES:
Garages shall have at least two (2) ceiling lights on a general lighting circuit, one ceiling receptacle on a fifteen (15) ampere circuit, and three (3) GFCI receptacles, one installed on each of three (3) different walls. All wall receptacles shall be on the same twenty (20) ampere circuit and separate from all other lighting and receptacles. All receptacles must be installed at least four feet (4') above finished floor. All outside doors shall be illuminated. All electrical feed to the garage shall be underground, in accordance with the minimum cover requirements found in table 18-27-300.5. Only rigid, IMC heavy wall or rigid nonmetallic (PVC, schedule 40, with ground wire) conduit shall be used to feed the garage. One end of the conduit or ground wire shall be grounded to the conduit system in the garage and other end to the nearest metallic ground within the house. Special permission will be given to overhead aerial wires. If the condition warrants this, if in writing, and the inspection department, upon investigation, is aware of existing conditions. (Ord. 01-09-32)