APPENDIX B: DENSITIES, LOT SIZES AND DIMENSIONS | |||||||||||||||||||
ZONING DISTRICT | Village | Waterfront Village | Town Edge | ||||||||||||||||
C | A/RB | H/R | WH/R | V-1 | V- R | NB | WV-1 | WV- R | WV-NB | WV-WC | ECC/R | TE-1 | TE- R | TE-NB | TE-CG | E1 | EB/C-1 | WW | |
Maximum density (# dwelling units per # acres) | 1:50 | 1:201 |
2:1 | 2:1 | 1:20 | 2:12 | 2:12 |
1:20 | 2:1 | 2:1 | None | 2:1 | 1:5 | 1:23 | 1:23 |
None | None | None | |
Minimum lot size | 1 acre | 1 acre4 |
1/2 acre | 1/2 acre | 1 acre | 1/2 acre | 1/2 acre | 1 acre | 1/2 acre | 1/2 acre | None | 1/2 acre | 1 acre | 1 acre | 1/2 acre | None | None | None | |
Minimum lot width in feet at: | |||||||||||||||||||
Measured at the building/ front setback line | 150 | 125 | 100 | 100 | 125 | 100 | P/none | 125 | 100 | P/none | P/none | 90 | 125 | 100 | None | None | None | None | |
Measured at the shoreline
| 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 (water dependent uses only, 60) | 250 | None | None | None | None | 250 | None | |
Minimum yard dimensions in feet: | |||||||||||||||||||
Front Yard Setback | |||||||||||||||||||
All structures measured from the property line on U.S. Rt. 13 | 100 | 100 | 100 | n/a | 100 | 100 | 100 | n/a | n/a | n/a | n/a | n/a | 100 | 100 | 100 | 100 | 100 | 100 | |
All structures measured from the right-of-way of all other roads and railroads
7 |
200 | 60 | P/60 | P/60 | 80 | P/60 | P/60 | P/80 | P/60 | P/10 | P/60 (water dependent uses only, 10) | P/20 | 60 | 60 | 60 | 100 | 100 7 |
100 | |
Rear Yard Setback | |||||||||||||||||||
Principal structures | 100 | 25 | 25 | 25 | 50 | 25 | 206 |
50 | 25 | 206 | 20 (water dependent uses only, 0)6 |
20 | 50 | 25 | 206 | 356 | 356 | 356 | |
Accessory structures
| 20 | 10 | 5 | 5 | 10 | 5 | 56 |
10 | 5 | 56 | 5 (water dependent uses only, 0)6 |
5 | 10 | 5 | 56 | 206 | 206 | 206 | |
Side Yard Setback | |||||||||||||||||||
Allowable principal attached structures measured from shared property lines | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 06 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
All other principal structures | 50 | 15 | 15 | 15 | 25 | 10 | 156 |
25 | 10 | 156 | 20 (water dependent uses only, 10)6 | 105 |
25 | 10 | 156 | 256 | 256 | 256 | |
Accessory structures
| 10 | 10 | 5 | 5 | 10 | 5 | 56 |
10 | 5 | 56 | 20 (water dependent uses only, 10)6 |
5 | 10 | 5 | 56 | 156 | 156 | 156 | |
Maximum height in feet:6 | |||||||||||||||||||
Principal structures
| 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 25 | 35 | 35 | 35 | 35 | 45 | 35 | |
Accessory structures | 25 | 25 | 25 | 25 | 25 | 20 | 20 | 25 | 20 | 20 | 25 | 16 | 25 | 16 | 20 | 25 | 30 | 25 | |
1 Density may be increased to 1:10 under open space density bonus option; 85% open space required; max. 2 With SUP, density may be increased to 4:1 for multi-family if one-site sewage and water supply systems are approved by the Health Department. 3 Through rezoning to TE/R or TE-NB, density may be increased to 5:1 if central water and sewer owned and operated by a municipality, county or public service authority are provided; setbacks may be modified. 4 Minimum lot size may be reduced to 30,000 sq. ft. under open space density bonus option. 5 In the case of zero lot line development or a shared lot line, a 20-ft. setback shall be observed on the other. 6 If a lot is zoned NB, WV-NB, WV-WC, TE-NB, TE-CG, EI, EB, C-1 or WW abuts a lot that is zoned NB, WV-NB, WV-WC, TE-NB, TE-CG, EI, EB, C-1 or WW, the side and / or rear minimum setback shall be reduced to 0 feet pursuant to §154.2.141 General Modification to Yard Regulations. 7 P/x = Prevailing, if one exists, otherwise number indicated. See § 154.2.142, Front Setback/Yard Regulations. Front setback from railroad right-of-way in E1 District is 0 feet. Note: Supplemental setback regulations are stated in § 154.2.140 et seq., Supplemental District Regulations. Note: All development requires Health Department approval.
| |||||||||||||||||||
(Ord. passed 4-12-2016
; Amendment adopted 7-11-2017
)