1339.02 SINGLE FAMILY DEVELOPMENT.
   All single family residential property being developed within the City shall now be required to comply with the following requirements:
   (a)   Drainage from sump pumps, roof drain connections and foundation drains shall not outlet onto the ground or through the curb into the street, but shall be connected to the storm water collection system. No storm drainage of any type shall be permitted to be discharged into sanitary sewers or combination sewers.
   (b)   Where an adequate storm water collection system is not available, drainage from sump pumps, roof drain connections and foundation drains shall be drained to leach beds with at least one half cubic yard of washed gravel per downspout and one cubic yard per sump pump. Such leach bed shall be located at least ten feet from any lot line.
   (c)   This section does not apply to additions, either attached or unattached, to any existing single family dwellings.
      (Ord. 91-15. Passed 5-20-91.)