§ 150.040 FOOTINGS.
   (A)   All footings shall bear on undisturbed soil. Where soil conditions prevent short-cut trenches for footings, side forms shall be used.
   (B)   The minimum dimensions of footings shall be as follows.
      (1)   Under foundation walls of 1-story frame dwellings containing no basement: thickness 6 inches; projection 3 inches on each side of wall.
      (2)   Under foundation walls of all other frame dwellings and 1-story masonry dwellings: thickness 7 inches; projection 4 inches on each side of wall.
      (3)   Under foundation walls of masonry dwellings more than 1 story in height: thickness 12 inches; projection 6 inches each side.
      (4)   Under masonry piers: thickness 12 inches; projection each side 6 inches, area 4 square feet.
      (5)   Under posts and columns: thickness 12 inches, size 2 x 2 feet.
      (6)   Under chimneys for 1-story dwelling: thickness 8 inches; projection on all sides 4 inches.
      (7)   Under chimneys for dwellings more than 1 story: thickness 12 inches; projection all sides 6 inches.
(1992 Code, § 7-32)