§ 151.131 PORTLAND CEMENT CONCRETE PAVEMENT.
   (A)   If the sub-divider elects to construct streets totally out of Portland cement concrete or if such pavement is required by the City Manager, thicknesses of seven inches for local and collector streets; seven and one-half inches for minor arterial streets; and eight inches for major arterial, commercial and industrial streets shall be required, and shall meet the current Plain Portland Cement Concrete Pavement Specifications of ODOT.
   (B)   The Commission may require pavements of greater thickness, upon the recommendation of the City Manager, based upon his or her evaluation of the sub-grade, traffic and wheel load conditions.
(Prior Code, § 23.05.27) Penalty, see § 151.999