Sign requirements are as described on the table that follows:
ZoningDistricts
|
UA Urban Agriculture District | R-A Low Density Residential District | R-B Traditional Residential District | R-C High Density Residential District | NC Neighborhood Mixed Use Commercial District | LC Limited Mixed Use Commercial District | VC Vehicle Oriented Commercial District | General Commercial District | M Manufacturing District | OU Other Uses District | Additional Standards |
ZoningDistricts
|
UA Urban Agriculture District | R-A Low Density Residential District | R-B Traditional Residential District | R-C High Density Residential District | NC Neighborhood Mixed Use Commercial District | LC Limited Mixed Use Commercial District | VC Vehicle Oriented Commercial District | General Commercial District | M Manufacturing District | OU Other Uses District | Additional Standards | |
Number of signs permitted per principal use (total) | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | ||
Maximum sign area for all signs associated with a principal use (sq. ft.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 1 sq. ft per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft per foot of frontal width of structure (100 sq. ft. max.) | ||
Freestanding Sign (Ground or Monument Sign) | Sign permitted in this zoning district? (yes or no) | No* | No* | No* | No* | No | No | Yes | Yes | Yes | Yes | *Only permitted if principal use is a non- residential use |
Maximum sign area (sq. ft.) | 15 | 15 | 15 | 15 | - | - | 35* | 35- | 35* | 35* | May be increased 20% (max. 42 sq. ft.) if sign is 7 ft. or less in height | |
Maximum sign height (ft.) | 6 | 6 | 6 | 6 | - | - | 20 | 20 | 20 | 20 | ||
Minimum sign setback (ft.) | 20 | 20 | 20 | 20 | - | - | Equal to sign height | Equal to sign height | Equal to sign height | Equal to sign height | ||
Freestanding Sign (Pole or Pylon Sign) | Sign permitted In this zoning district? (yes or no) | No* | No* | No* | No* | No | No | Yes | Yes | Yes | Yes | *Only permitted if principal use is a non- residential use |
Additional criteria requited to permit this sign type | - | - | - | - | - | - | Frontage >200 ft. | Frontage >200 ft. | Frontage >200 ft. | Frontage >200 ft. | ||
Maximum sign area (sq. ft.) | 15 | 15 | 15 | 15 | - | - | 35* | 35* | 35* | 35* | *May be increased 20% (max. 42 sq. ft.) if sign is 7 ft. or less in height | |
Maximum sign height (ft.) | 6 | 6 | 6 | 6 | - | - | 20 | 20 | 20 | 20 | ||
Minimum sign setback (ft.) | 20 | 20 | 20 | 20 | - | - | Equal to sign height | Equal to sign height | Equal to sign height | Equal to sign height | ||
Wall Sign | Sign permitted in this zoning district? (yes or no) | No* | No* | No* | No* | Yes | Yes | Yes | Yes | Yes | Yes | *Only permitted if principal use is a non- residential use |
Maximum sign area (sq. ft.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 15% of facade area (50 sq. ft. max.)* | 15% of facade area (50 sq. ft. max.)* | 15% of facade area (50 sq. ft. max.)* | 15% of facade area (50 sq. ft. max.)* | 15% of facade area (50 sq. ft. max.)* | 15% of facade area (50 sq. ft. max.)* | *For corner lots: wall sign(s), may be placed on either facade, both total area of wall sign shall not exceed 70 sq. ft. | |
Maximum sign height (ft.) | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | Main cornice of the building | ||
Projecting Sign | Sign permitted in this zoning district? (yes or no) | No | No | No | No | Yes | Yes | Yes | Yes | No | No | |
Maximum sign area (sq. ft.) | - | - | - | - | 15 | 15 | 15 | 15 | - | - | ||
Maximum extension from building wall (ft.) | - | - | - | - | 6 | 6 | 6 | 6 | - | - | Projecting signs shall not extend into adjacent street right- of-way | |
Minimum sign height (feet) | - | - | - | - | 12 | 12 | 12 | 12 | - | - | ||
Sign height (ft.) | - | - | - | - | Maximum height: top of first floor or 15 ft., whichever is less | Maximum height: top of first floor or 15 ft., whichever is less | Maximum height: top of first floor or 15 ft., whichever is less | Maximum height: top of first floor or 15 ft., whichever is less | - | - | ||
Directional sign | Sign permitted in this zoning district? (yes or no) | No* | No* | No* | No* | Yes | Yes | Yes | Yes | Yes | Yes | *Only permitted if principal use is a non- residential use |
Maximum sign area (sq. ft.) | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | ||
Maximum sign height (ft.) | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | ||
Minimum sign setback (ft.) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | ||
Number of signs permitted per principal use (total) | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | ||
Maximum sign area for ail signs associated with a principal use (sq. ft.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 10% of facade-area (40 sq. ft. max.) | 1 sq. ft. per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft. per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft. per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft. per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft. per foot of frontal width of structure (100 sq. ft. max.) | 1 sq. ft. per foot of frontal width of structure (100 sq. ft. max.) | ||
Temporary Sign | Sign permitted In this zoning district? (yes or no) | No* | No* | No* | No* | Yes | Yes | Yes | Yes | Yes | Yes | *Only permitted if principal use is a non- residential use |
Maximum sign area (sq. ft.) | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 | ||
Additional requirements | Temporary signs may be erected a maximum of 2 times during a 12-month period for up to 2 weeks at a time | |||||||||||
A-Frame or Sandwich Board Signs | Sign permitted In this zoning district? (yes or no) | No | No | No | No | Yes | Yes | Yes | Yes | No | No | Allowed on a sidewalk immediately in front of the business during hours of operation; a certificate of insurance naming the borough of Carnegie as an additional insured shall be provided. Permits shall be renewed annually from date of issue. |
Maximum sign area (sq. ft.) | - | - | - | - | 10 | 10 | 10 | 10 | - | |||
Additional requirements | - | - | - | - | 1 sign allowed per business 5 ft. of clear pedestrian passage on the sidewalk must be maintained | - | ||||||
Home Occupation Sign | Sign permitted In this zoning district? (yes or no) | Yes | Yes | Yes | Yes | No | No | No | No | No | No | |
Maximum sign area (sq. ft.) | 4 | 4 | 4 | 4 | - | - | - | - | - | - | ||
Minimum sign setback (ft.) | 10 | 10 | 10 | 10 | - | - | - | - | - | - | ||
Off-Premises Advertising Sign | Sign permitted In this zoning district? (yes or no) | No | No | No | No | No | No | No | No | Yes | No | Allowed as a conditional use |
Maximum sign area (sq. ft.) | - | - | - | - | - | - | - | - | - | - | ||
Maximum sign height (ft.) | - | - | - | - | - | - | - | - | - | - | ||
Electronic Off-Premises Advertising Sign (Electronic Billboard) | Sign permitted In this zoning district? (yes or no) | No | No | No | No | No | No | No | No | Yes | No | Allowed as a conditional use |
Maximum sign area (sq. ft.) | - | - | - | - | - | - | - | - | - | - | ||
(Ord. 1089, passed 5-19-2014)